background image

OPERATING INSTRUCTIONS

CONTROLS

The refrigerator can be run on either 230 V,  12 V or

LP gas. Changing between these modes of operation

is carried out by means of the controls of the control

panel shown in fig 1.
Two rocker switches are used to select the electric

power supply, one for 230 V (B) and one for 12 V (A).
Refrigerator temperature is controlled by a thermostat

(C) when the unit runs on 230 V. The gas supply is

turned on/off by means of the knob (D). When

lighting the gas, one must press in the knob

as explained further on.
Refrigerator temperature is controlled by a thermostat

(E) when the refrigerator runs on LP gas. Please note

that the thermostat has no “off” position.
In model RM 4361MD, the gas flame is electronically

lit, monitored and relit if necessary. For this the toggle

switch (F) should be “on” during gas operation.

An indicator lamp in the switch flashes when the

automatic igniter attempts to light the burner.

Otherwise this lamp is off.

STARTING THE REFRIGERATOR

The position numbers refer to fig.1.

CAUTION!

Only use one source of energy at a time!

LP Gas operation

After initial installation, servicing, or changing gas

cylinders etc., the gas pipes may contain some air

which should be allowed to escape by briefly turning

on the refrigerator or other appliances. This will

ensure that the flame lights immediately.
To start gas operation:

1. Open the shut-off valve of the gas bottle (check

that there is enough gas). Open any on-board 

shut-off valve.

2. Check that the switches for mains and 12 V opera-

tion are off.

3. Turn on the gas supply by pressing the (D) knob

and turning it to the “big flame” position

4. Set the thermostat knob (E) to the highest setting.

5. Throw on switch (F). A light in the switch should 

now start to flash, indicating that sparks are being

generated at the burner.

6. Press the (D) button. This opens the flame failure 

device and allows gas to flow to the burner.

7. When the flame lights, the sparking stops automa

tically and the switch stops flashing.

8. Keep the (D) button pressed for a further 10 to 15

seconds to active the flame failure device, then

release it.

230 V Operation

1. Turn off gas or 12 V operation when applicable.

2. Turn the knob (C) of the thermostat to its highest

(coldest) position.

3. Set switch (B) to position I. The switch will light up

green when the power supply is connected.

12 V Operation

Only operate your refrigerator on 12 V when the

engine of the vehicle is running - otherwise your

battery will soon be discharged.

1. If applicable, turn off the gas operation.

2. Set the 12 V rocker switch (A) to I. The switch will

light up red when the power supply is connected.

WINTER OPERATION

Please check that the ventilation grilles or the flue

outlet are not blocked by snow, leaves etc.

DOMETIC

ventilation grilles  can be fitted with winter

covers, to protect the cooling unit against cold air.

The covers may be fitted when the outside

temperature is below approx. 10°C and should be

fitted when the temperature is below the freezing

point.

We suggest that you fit the winter covers also in the

case that the vehicle is laid up during the winter

months.

REGULATING THE TEMPERATURE

The position number refers to fig. 1.
It will take a few hours for the refrigerator to reach

normal operating temperature. So we suggest you

start it well in advance of a trip and if possible store it

with precooled foodstuffs.
On 230 V operation the refrigerator is controlled by a

thermostat and the thermostat knob (C) should be set

at 3-5. If a lower (colder) temperature is desired, set

the thermostat to a higher figure.
On 12 V operation the refrigerator works

continuously.
On LP gas operation the refrigerator temperature is

regulated by the gas thermostat (E), which should be

set at 3-5. If a lower (colder) temperature is desired,

set the thermostat to a higher figure.

FIG.1

9

Summary of Contents for RM 4361DM

Page 1: ... 4361NDM Typ C40 110 821 2684 50 T B 10 03 ABSORBER KÜHLSCHRANK für CARAVAN und REISEMOBIL BEDIENUNGSANLEITUNG EINBAUANLEITUNG Deutsch Seite 2 English page 8 MANUAL ABSORPTION REFRIGERATOR for CARAVAN and MOTORHOME ...

Page 2: ...the data plate inside the refrigerator to ensure that you have received the right model The data plate contains informations about the right AC voltage and gas pressure The data plate contains e g the following details Model designation RM 4361DM RM 4361NDM Product number Serial number Since these details will be needed if you have to contact service personnel it is a good idea to make a note of t...

Page 3: ... Press the D button This opens the flame failure device and allows gas to flow to the burner 7 When the flame lights the sparking stops automa tically and the switch stops flashing 8 Keep the D button pressed for a further 10 to 15 seconds to active the flame failure device then release it 230 V Operation 1 Turn off gas or 12 V operation when applicable 2 Turn the knob C of the thermostat to its h...

Page 4: ...ind of heating appliance as this might damage the plastic surfaces of the refrigerator Neither should any sharp objects be used to scrape off the ice The defrost water runs from a collector channel to a receptacle at the rear of the refrigerator where it eva porates Defrost water in the freezer compartment should be mopped up with a cloth When the ice has melted wipe the refrigerator dry and resta...

Page 5: ... conditions appli cable for the country concerned For warranty or other servicing please contact our Dometic Service depart ment Any damage due to improper use is not covered by the warranty The warranty does not cover any modifications to the appliance or the use of non origi nal Dometic parts the warranty does not apply if the installation and operating instructions are not adhe red to and no li...

Page 6: ... must be at least 2 5 mm if the distance is less than 9 meters and at least 4 mm if the distance is more than 9 meters To ensure satisfactory operation the positive lead must be fitted with a fuse rated at max 16 A To prevent the refrigerator from draining the battery make sure that the current supplied to the caravan is cut off when the vehicle engine is not running for example by fitting an igni...

Page 7: ...13 DECLARATION ...

Page 8: ... Dometic GmbH 2002 Änderungen vorbehalten Subject to change without notice Dometic GmbH In der Steinwiese 16 D 57074 Siegen www dometic de caravan www dometic com ...

Reviews: