EN
PerfectPower
Fastening and connecting the inverter
15
Connecting the inverter to the 230 V mains supply
➤
Plug the 230 V connection cable into the connector for the 230 V power supply
to the inverter (fig.
1
2, page 3).
➤
Connect the 230 V connection cable to a 230 V socket in the vehicle.
Connecting the remote control to the inverter
➤
Switch off the inverter.
➤
Insert the cable end of the remote control into the connection (fig.
2
2,
page 3).
➤
Set the main switch (fig.
2
1, page 3) to “Remote”.
Connecting the external switch contact to the inverter
➤
Switch off the inverter.
➤
Connect the external switch contact (power supply from the inverter) at the
remote port (fig.
2
3, page 3) in accordance with the wiring diagram (fig.
3
,
page 3),
➤
Set the main switch (fig.
2
1, page 3) to “Remote”.
I
8.3
Connecting multiple consumers
!
The device is equipped at delivery with galvanic isolation. For the safe operation of
multiple consumers, it is essential that a circuit breaker (residual current circuit
breaker) is built into the socket distribution circuit, see sample circuit diagram in
fig.
6
, page 5.
NOTE
If you wish to use an external switch contact with a power supply of it
own, e.g. the ignition, you must interconnect a suitable relay.
WARNING! Danger of electrocution!
If you wish to connect more than one consumer to the inverter and install
a socket distribution circuit, you must arrange a circuit breaker (residual
current circuit breaker) and set a grounding bridge in the inverter. The
grounding bridge may only be connected by a trained professional who
is familiar with the relevant VDE (German Engineering Society) regula-
tions.