- 13 -
replacing the fuses
power module
To replace the fuses, follow these steps:
Disconnect 120
1.
V AC and 12V DC power.
Remove the power module cover.
2.
Snap the fuse out of the fuse holder.
3.
Fit a new fuse in to the fuse holder.
4.
Put back the power module cover.
5.
inline Fuse
The 3 A inline fuse for the power vent fans is connected to the
12V DC socket. To replace the inline fuse, follow these steps:
Disconnect 12
1.
V DC power.
open the fuse holder.
2.
Replace the fuse.
3.
Put the holder back together.
4.
maintenance & service
replacing the heater
The heat necessary for the operation of an absorption cooling
unit is supplied by an electric heater mounted in a pocket of the
boiler system. The refrigerator is equipped with a series con-
nected twin heater.
To replace the heater, follow these steps:
Disconnect 120
1.
V AC and 12V DC power.
Remove the protection cover.
2.
Remove the power module cover.
3.
Disconnect the heater leads.
4.
With a pair of pliers, unfold the lug holding the lid of
5.
the boiler casing and open the lid.
Remove some insulation wool so that the heater is
6.
accessible.
Turn and lift the heater out of its pocket.
7.
Fit the new heater into the pocket.
8.
Connect the leads.
9.
Put back the power module cover.
10.
Put back the insulation wool. Close the lid of the
11.
boiler.
Put back the protection cover.
12.