![Dometic MCA1215 Installation And Operating Manual Download Page 30](http://html1.mh-extra.com/html/dometic/mca1215/mca1215_installation-and-operating-manual_2518432030.webp)
EN
Technical data
MCA1215, MCA1225, MCA1235
30
Protective devices
Input data
Testing/certification:
In compliance with the EMC directive
2004/108/EC including 2009/19/EC and
the Low-voltage Directive 2006/95/EC
EN 60335-1
EN 60335-2-29
EN 55022
EN 61000-3-2
EN 61000-3-3
EN 61000-4-2, 3, 4, 5, 6, 8, 11
ENV 50204
In compliance with Australian standard
AS/NZS60335.2.29 and IEC60068.2.6
MCA12xx
Output side short circuit:
Current is reduced to 25% of the maximum
current
Overvoltage:
16 V
Protection class:
IP21
Battery charger over temperature:
100 °C ± 5 °C (measured internally)
Battery over temperature:
52 °C ± 5 °C (with battery sensor)
MCA1215
MCA1225
MCA1235
Rated input voltage:
200 – 240 V
w
Output factor correction:
> 97% (full load)
Input frequency:
50 Hz – 60 Hz
Efficiency at 240 V
?
w
87%
Leakage current:
< 1 mA at 240 V
w
Input current at 240 V
?
w
1.07 A 1.8 A
2.8 A
MCA12xx
MCA1215-1235--IO--AU.book Seite 30 Donnerstag, 13. Oktober 2016 10:37 10