EN
Connecting the device
MCA1215, MCA1225, MCA1235
24
➤
Use the DIP switches (fig.
a
, page 24 ) to set the required functions and values:
–
To set the absorption voltage:
–
To set the floating voltage:
–
To set the power supply mode (recommended for Dometic eStore batteries):
–
Enabling the control for external devices (such as MPC01, does not apply to
MCA-RC1)
Switch 1
Switch 3
Switchover voltage
ON
OFF
14.4 V
OFF
OFF
14.7 V
Switch 2
Switch 3
Retention voltage
ON
OFF
13.5 V
OFF
OFF
13.8 V
Switch 1
Switch 2
Switch 3
Constant voltage
OFF
OFF
ON
13.2 V
OFF
ON
ON
13.8 V
ON
OFF
ON
14.4 V
DC OUTPUT
STATUS
1
OFF
ON
2 3 4
a
MCA1215-1235--IO--AU.book Seite 24 Donnerstag, 13. Oktober 2016 10:37 10