![Dometic IB36H401RI Installation Manual Download Page 14](http://html.mh-extra.com/html/dometic/ib36h401ri/ib36h401ri_installation-manual_2518281014.webp)
AU
Installation
IBIS4
14
See fig.
0
A
➤
Seal the screw holes and recesses with a flexible non-hardening butyl sealing
compound (e.g. SikaLastomer-710, Selleys Butyl Mastic, Bostik ezycaulk
butyl sealant, or similar products).
8.4
Laying the connecting cables
D
The roof air conditioner must be connected to an electric circuit which is able to
supply the required current (see Technical data in Operating Manual).
➤
Select the cross-section of the cable corresponding to the length:
–
Length < 7.5 m: 1.5 mm²
–
Length > 7.5 m: 2.5 mm²
See fig.
a
➤
Make an opening on one side in order to feed through the electrical power
supply cable.
➤
Feed the mains cable through the opening into the vehicle interior.
8.5
Installing the roof air conditioner ADB
A
NOTICE!
Observe the sealant manufacturer’s instructions.
DANGER! Danger of electrocution
Make sure there is no voltage at electrically operated components before car-
rying out work on them!
NOTICE! Risk of damage
Observe the structural strength of the roof of the vehicle. The roof of the vehicle
must be able to bear the weight of the roof air conditioner. The roof must not
be indented or deformed by the weight of the unit, even over a longer period
of time.
a
IBIS4-A4--I.book Seite 14 Mittwoch, 13. März 2019 9:43 21