Making a new opening

See fig.

5

Select an area at the centre on the roof between two longitudinal supports.

Mark the position and size of the opening (preferably 400 x 400 mm or 
optionally 360 x 360 mm).

See fig.

6

Drill out the corners (

A

).

Carefully cut out the opening on the roof using a keyhole saw or a similar tool 
(

B

).

Make sure no electrical power cables are damaged.

1112

20 – 1

0

0

758

24

0

579 

85

93

518

=

=

48

105

113

360

400

A

B

400 mm

400 mm

360 mm

360 mm

63

649

360

43

629

400

5

6

A

B

IBIS4-A4--I.book  Seite 11  Mittwoch, 13. März 2019  9:43 21

Summary of Contents for IB36H401RI

Page 1: ...CLIMATE CONTROL IBIS4 IB36H401RI IB36H401RIY Air conditioning roof unit Installation Manual EN IBIS4 A4 I book Seite 1 Mittwoch 13 März 2019 9 43 21 ...

Page 2: ...IBIS4 A4 I book Seite 2 Mittwoch 13 März 2019 9 43 21 ...

Page 3: ...6 6 Intended use 7 7 Labels 7 8 Installation 8 1 Explanation of symbols D A I DANGER Safety instruction Indicates a hazardous situation that if not avoided will result in death or serious injury WARNING Safety instruction Indicates a hazardous situation that if not avoided could result in death or serious injury CAUTION Safety instruction Indicates a hazardous situation that if not avoided could r...

Page 4: ...out of reach of children or infirm persons Do not allow them to use electrical devices without supervision Persons whose physical sensory or mental capabilities or whose lack of experience and knowledge prevent them from using the device safely should not use it without supervision or instruction by a responsible person Do not undo the upper cover of the roof air conditioner in the event of a fire...

Page 5: ... altered IBIS4 increased height 230 mm 2 2 Handling electrical cables WARNING The electrical power supply may only be connected by a qualified electrician The appliance shall be installed in accordance with national wiring regula tions CAUTION Attach and lay the cables so that they cannot be tripped over or damaged A NOTICE Use cable ducts to lay cables through walls with sharp edges Do not lay lo...

Page 6: ...cription 1 1 Roof air conditioner 2 1 Roof plate 3 1 Air distribution box ADB 4 1 ADB centre cover 5 5 Duct sections 6 3 Cable connectors 7 4 Long fastening bolts 8 1 Remote control with batteries Description Duct section Additional duct sections to allow fitment to thicker roof 1 2 3 4 5 6 7 8 1 IBIS4 A4 I book Seite 6 Mittwoch 13 März 2019 9 43 21 ...

Page 7: ... work properly if exposed to strong vibrations The function of the roof air conditioner is guaranteed for temperatures between 2 C and 52 C I 7 Labels Labels are attached to the IBIS4 roof air conditioners These labels provide the user and fitter with information on specifications of the device Theroofairconditionerlabelislocatedonthesideoftheelectronicsboxandcan be seen through the side vent The ...

Page 8: ...tallation of the roof air conditioner can result in irreparable damage to the device and put the safety of the user at risk The manufacturer assumes no liability for malfunctions and for the safety of the roof air conditioner especially for injury and or damage to property if the roof air conditioner is not fitted in accordance with these installation instructions Always wear the recommended prote...

Page 9: ...er such as lamps cupboards doors Before installation find out by consulting the manufacturer of the vehicle whether the construction is designed for the static weight and the loads of theairconditionerwhenthevehicleisinmotion Themanufactureroftheroof air conditioner assumes no liability whatsoever The vehicle manufacturer may have already provided points where the open ing for the installation of ...

Page 10: ...nect the roof air conditioner to the electrical power Check that the voltage specification on the type plate is the same as that of the power supply Do not lay cables which are loose or bent next to electrically conductive material metal Install an all pole switch with a contact opening width of at least 3 mm on the installation side Ensure that the mains voltage supply has a residual current circ...

Page 11: ...ferably 400 x 400 mm or optionally 360 x 360 mm See fig 6 Drill out the corners A Carefully cut out the opening on the roof using a keyhole saw or a similar tool B Make sure no electrical power cables are damaged 1112 20 100 758 240 579 85 93 518 48 105 113 360 400 A B 400 mm 400 mm 360 mm 360 mm 63 649 360 43 629 400 5 6 A B IBIS4 A4 I book Seite 11 Mittwoch 13 März 2019 9 43 21 ...

Page 12: ...roof 8 3 Installing in an existing opening I NOTE Existing roof hatch openings in accordance with fig 8 are suitable for installing the roof air conditioner Dispose of all waste material glue silicone and seals separately Observe the disposal guidelines The manufacturer only assumes liability for parts included in the scope of delivery The validity of the warranty expires if the device is installe...

Page 13: ...crews and fixtures of the existing roof hatch or air conditioner Take out the roof hatch or air conditioner See fig 9 Remove the sealant around the opening using a scraper or similar tool 8 9 0 IBIS4 A4 I book Seite 13 Mittwoch 13 März 2019 9 43 21 ...

Page 14: ... See fig a Make an opening on one side in order to feed through the electrical power supply cable Feed the mains cable through the opening into the vehicle interior 8 5 Installing the roof air conditioner ADB A NOTICE Observe the sealant manufacturer s instructions DANGER Danger of electrocution Make sure there is no voltage at electrically operated components before car rying out work on them NOT...

Page 15: ...g butyl sealing com pound e g SikaLastomer 710 Selleys Butyl Mastic Bostik ezycaulk butyl sealant or similar products See fig c Lift the roof air conditioner onto the roof of the vehicle Position the roof air conditioner onto the roof plate and align into the groove in the base pan Observe the direction of travel b c IBIS4 A4 I book Seite 15 Mittwoch 13 März 2019 9 43 21 ...

Page 16: ...tallation IBIS4 16 Attaching the roof air conditioner See fig d Use the corners of the front of the base pan to help align the unit with the roof plate d IBIS4 A4 I book Seite 16 Mittwoch 13 März 2019 9 43 21 ...

Page 17: ...er 10 Out air sensor 11 Evaporator sensor 12 Condenser sensor 13 Discharge sensor 14 Inductor ye yellow bn brown bu blue gn green vt violet rd red wh white bk black 0 0 0 0 L N CN5 COMU ye gn ye gn bu bn ye gn ye ye vt vt bk wh rd rd rd ye bk bk bu br br wh wh ye gn ye gn ye gn N1 4V W V U PE AC N AC L LX1 CN1 CN2 CN3 CN4 LX2 RT1 RT2 RT3 RT4 2 3 4 5 6 14 13 12 11 10 7 8 9 1 e IBIS4 A4 I book Seite...

Page 18: ... voltage supply Connect the cables 1 to a cable connector 2 Communication cable Pull out the filter slightly to create a gap for the communication cable 3 Feed the communication cable through the gap and locate the wire in the opening 1 2 3 1 2 3 f IBIS4 A4 I book Seite 18 Mittwoch 13 März 2019 9 43 21 ...

Page 19: ...guide I Attach the required number of duct sections on the ADB Fasten the ADB to the ceiling through to the roof air conditioner with the 4 bolts supplied Roof thickness Number of duct sections 18 28 mm 1 28 38 mm 2 38 48 mm 3 48 58 mm 4 58 68 mm 5 NOTE Additional duct sections can be purchased for thicker roofs g IBIS4 A4 I book Seite 19 Mittwoch 13 März 2019 9 43 21 ...

Page 20: ...2 in the ADB Ensure the cable is located into the small opening away from the filter area Secure excess cable into the holders Push the filter back fully in See fig i Clip the centre cover to the ADB The installation is now completed Connect to the power and test NOTICE Risk of damage Tighten to the specified torque Do not overtighten A 2 5 0 3 Nm h click click i IBIS4 A4 I book Seite 20 Mittwoch ...

Page 21: ... current in cooling mode 6 9 A Rated current in heating mode 6 5 A Required fuse 10 A Operating temperature range 2 C to 52 C Refrigerant R 410A Refrigerant quantity 0 750 kg CO2 equivalent 1 566 t Global warming potential GWP 2088 Protection class outdoor unit IPX4 Suggested max vehicle length with insulated walls 7 m Dimensions L x W x H height above vehicle roof 1112 x 758 x 230 mm Total instal...

Page 22: ...IBIS4 A4 I book Seite 22 Mittwoch 13 März 2019 9 43 21 ...

Page 23: ...IBIS4 A4 I book Seite 23 Mittwoch 13 März 2019 9 43 21 ...

Page 24: ...OCAL DEALER dometic com dealer YOUR LOCAL SUPPORT dometic com contact dometic com 1 01 1 0ķ 4 0 1 1 2 ķ 2 1 2 9 0 ĸ DOMETIC GROUP AB 3E 0 1 ĉč ŖĉďĉčČ 4 4445102830 4450017950 54 606 MA02 03 2019 IBIS4 A4 I book Seite 24 Mittwoch 13 März 2019 9 43 21 ...

Reviews: