Technical description
15
7.1
Components
The refrigerant circuit of the roof air conditioner consists of five main components
(fig.
1
, page 3):
•
Compressor
(
1
)
The compressor draws in the R407c refrigerant used and compresses it. This
raises the pressure and therefore the temperature of the refrigerant.
•
Condenser
(
2
)
The built-in liquefier works like a cooler or heat exchanger. The air flowing past
absorbs the heat and the hot refrigerant gas cools down and becomes liquid.
•
Evaporator
(
3
)
The evaporators cool down and dehumidify the air flowing past them. The
refrigerant absorbs the heat and vaporises.
•
Blower (4)
A blower distributes the cooled air within the vehicle through an air outlet unit.
•
Solenoid valve
(
5
)
The solenoid valve allows the cooling cycle to be reversed and the air feeding in
to be heated.
Overview of all parts: fig.
a
, page 8.