background image

EN

FreshJet

Technical description

17

The following control and display elements are available on the remote control 
(fig.

6

, page 16) :

No.

Explanation

1

Digital display

Displays the following:

Time

Selected room temperature (target value) in °C or °F

Actual room temperature

Air conditioning mode

Blower level

Symbols for active additional functions

Battery status

2

 button

Switches the air conditioner and remote control on or to stand-by mode 

3

 button

Selects the blower setting

4

MODE

 button

Selects the air conditioning mode

5

 button

Activates the sleep function. The sleep function automatically modifies the target 
value to provide a pleasant sleeping temperature.

6

 button

Press once:

Press again:

Displays the current interior temperature

(symbol

 is displayed).

Displays the set temperature.

7

 button

Activates the “I feel” function. Every 10 minutes, the “I feel” function adjusts the 
target temperature to the temperature measured by the remote control.

8

°C/°F

 button

Switches between temperature units Celsius (°C) and Fahrenheit (°F)

9

 button

Sets the timer and the clock

10

SET

 button

Confirms and saves settings

FreshJet-ADB2015-O-AU.book  Seite 17  Freitag, 26. Januar 2018  9:19 09

Summary of Contents for FJ 2200

Page 1: ...FJ 2200 FJ 3200 Air conditioning roof unit Operating manual EN AIR CONDITIONERS FRESHJET ...

Page 2: ......

Page 3: ...Remote control 16 6 4 Air conditioning modes 19 6 5 Additional functions 20 7 Before initial use 21 8 Operating the roof air conditioner 22 8 1 Basic notes on operation 22 8 2 Using the remote control 22 8 3 Hint for improved use 23 8 4 Switching the roof air conditioner on and off 24 8 5 Selecting the air conditioning mode 25 8 6 Selecting the blower setting manually 25 8 7 Setting the temperatur...

Page 4: ...sal 39 14 Technical data 41 1 Explanation of symbols A I WARNING Safety instruction Failure to observe this instruction can cause fatal or serious injury CAUTION Safety instruction Failure to observe this instruction can lead to injury NOTICE Failure to observe this instruction can cause material damage and impair the function of the product NOTE Supplementary information for operating the product...

Page 5: ...firm persons Do not let them use the appliances without supervision Persons whose physical sensory or mental capabilities or whose lack of experience and knowledge prevent them from using the device safely should not use it without supervision or instruction by a respon sible person Only use the device as intended Do not make any alterations or conversions to the device Installation maintenance an...

Page 6: ...our vehicle documents needs to be altered FreshJet 2200 increased height 225 mm FreshJet 3200 increased height 248 mm If faults occur in the roof air conditioner s refrigerant circuit the roof air conditioner must be checked by a specialist company and properly repaired The refrigerant must never be released into the air 2 2 Operating the device safely WARNING Always disconnect the power supply wh...

Page 7: ... Dometic FreshJet 2200 roof air conditioner with heating 9105306512 Installation manual Operating manual Designation Reference No Dometic FreshJet 3200 roof air conditioner with heat pump and soft start 9105306660 9105306659 Installation manual Operating manual Designation Reference No Chillout ADB 9105306662 9600008662 ...

Page 8: ...midified air without dust and dirt Dimmable LED lamps integrated in the air outlet unit provide pleasant lighting LED lights are available only on specific model The roof air conditioner is operated with the remote control I The roof air conditioner is protected against over voltage When the supply voltage is above 265 V the roof air conditioner stops working It resumes normal service when the sup...

Page 9: ...EN FreshJet Technical description 9 6 1 Components 1 2 4 3 FreshJet 2200 FreshJet 3200 1 2 4 3 1 ...

Page 10: ...fier works like a cooler or heat exchanger The air flowing past absorbs the heat and the hot refrigerant gas cools down and becomes liquid Evaporator 3 The evaporators cool down and dehumidify the air flowing past them The refrigerant absorbs the heat and vaporises Blower 4 A blower distributes the cooled air within the vehicle through an air outlet unit Overview of all parts FreshJet 2200 availab...

Page 11: ...EN FreshJet Technical description 11 FreshJet 2200 2 ...

Page 12: ...EN Technical description FreshJet 12 FreshJet 3200 3 ...

Page 13: ...EN FreshJet Technical description 13 4 ...

Page 14: ...EN Technical description FreshJet 14 6 2 Control panel The control panel is at the air outlet unit of the roof air conditioner 4 3 2 1 5 ...

Page 15: ...s in winter mode Red light Only if the system is connected to 12 Vg the supply voltage of 230 Vw is not available Flashing red Over voltage The roof air conditioner resumes normal service when the supply voltage is within the allowed range Slowly flashing red light Malfunction in interior temperature sensor E1 Quickly flashing red light Malfunction in exterior temperature sensor E2 2 button Switch...

Page 16: ... description FreshJet 16 6 3 Remote control All settings of the device e g temperature settings timer programming are transmitted to the roof air conditioner by remote control 1 7 6 13 12 15 14 2 4 3 11 10 9 5 8 6 ...

Page 17: ...lects the blower setting 4 MODE button Selects the air conditioning mode 5 button Activates the sleep function The sleep function automatically modifies the target value to provide a pleasant sleeping temperature 6 button Press once Press again Displays the current interior temperature symbol is displayed Displays the set temperature 7 button Activates the I feel function Every 10 minutes the I fe...

Page 18: ... switched off 12 button Increases the value 13 button Reduces the value 14 Symbol batteries empty Is displayed when the batteries in the remote control are empty If this happens replace the batteries see chapter Replacing the remote control batteries on page 32 15 Symbol transmitting values Is displayed briefly when the remote control is transmitting values to the air conditioner No Explanation ...

Page 19: ...is mode Cooling You specify the temperature and blower settings and the air conditioner cools the interior to this tempera ture Heating Available for models with heating only You specify the temperature and blower settings and the air conditioner heats the interior to this tempera ture Circulating air You specify the blower level and the air conditioner blows air into the interior Dehumidification...

Page 20: ...itched on and off at the specified times Sleep The set temperature is modified by 1 C after one hour and by 2 C after two hours to generate a pleasant temperature for sleeping I feel The remote control measures the room temperature and transmits this measurement to the air conditioner every 10 minutes The air conditioner adapts the target value to this measurement Winter mode The winter mode avoid...

Page 21: ...e at maximum capacity Setting the time Set the current time see chapter Setting the time on page 32 Set the remote control Insert the batteries see chapter Replacing the remote control batteries on page 32 The display shows all symbols for 5 seconds Press simultaneously the button and the button during this 5 seconds The display shows the default model number Press simultaneously and button within...

Page 22: ...nditioner with the remote control You can transmit the values directly to the roof air conditioner when you set them You can first specify all values on the remote control and then transmit them collectively to the roof air conditioner Operating mode Features Off The roof air conditioner is switched off The remote control is inactive Stand by The roof air conditioning is ready for operation and ca...

Page 23: ...ipt of data with a high note Switching only the remote control to or from stand by In stand by mode the remote control display shows only the time IftheremotecontrolisnotpointingtotheIRreceiver fig 5 page 14 onthecontrol panel you can activate the remote control or switch it to stand by independently from the roof air conditioner Press the button 8 3 Hint for improved use The following hints will ...

Page 24: ... values that were set most recently NOTE The roof air conditioner can only be operated by the remote control when it is switched on or in stand by mode You can use the remote control to switch the roof air conditioner to and from stand by mode Press the button Available for models with heating only Ifyouswitchoftheroofairconditionerfromthe Heating mode using the remote control the blower continues...

Page 25: ...ower controls the strength of the air supply In the Cooling and Circulating air modes the blower levels can be selected manually In the other air conditioning modes the roof air conditioner controls the blower level automatically Use the button to select the desired blower level The roof air conditioner confirms the receipt of the values with a high note The new blower level has been set Display m...

Page 26: ...f air conditioner Heating Mode available for models with heating only In the Automatic and Heating modes you can specify a temperature between 16 C and 31 C via the remote control Use the or button to select the desired temperature The roof air conditioner confirms the receipt of the values with a high note The temperature is set on the roof air conditioner 8 8 Adjusting the air nozzles The air su...

Page 27: ...f air conditioner The switch on time is set on the roof air conditioner The roof air conditioner is switched on with the selected air conditioning mode at the specified time Switch the roof air conditioner to stand by Setting the switch off time Press the button twice The OFF symbol flashes on the display of the remote control Use the or button to set the time when the roof air conditioner is to s...

Page 28: ... the or button to set the time when the roof air conditioner is to switch off Press the SET button to transmit the value to the roof air conditioner The switch on and switch off times are set on the roof air conditioner The roof air conditioner starts in the selected air conditioning mode at the speci fied time and runs until the second specified time Switch the roof air conditioner to stand by Ca...

Page 29: ...hours to ensure a pleasant temperature for sleeping Set the required temperature see chapter Setting the temperature on page 26 Press the button The symbol appears in the display The sleep function is activated To deactivate the sleep function press the button again I NOTE The sleep function is deactivated in Circulating air mode NOTE The sleep function is deactivated if the MODE button is pressed...

Page 30: ...on The symbol appears in the display The I feel function is activated Position the remote control so that it points at the IR receiver fig 5 page 14 on the control panel Otherwise the values cannot be transmitted to the roof air conditioner I When thetemperaturerisesabove 29 Corfallsbelow 18 C the Ifeel function is deactivated The symbol flashes three times in the display and then turns off NOTE T...

Page 31: ...een dimmed to the required brightness Switching the light on off with the remote control Press the button to switch the lamps on or off The symbol appears in the display when the lights are turned on Dimming the light with the remote control Press the button for 2 s The symbol flashes in the display Press and hold the button or the button until the lights have been dimmed to the required brightnes...

Page 32: ...th general household waste Return any used batteries to your retailer or take them to a collection point 8 14 Setting the time The remote control needs the current time in order to program the timer The time is indicated on the display of the remote control Perform the following steps to set the time I Press and hold the button for 2 s The time flashes on the display of the remote control Use the ...

Page 33: ... winter mode is a special heating mode that starts at a temperature of 7 C and stops when the temperature rises above 10 C Press both buttons on the control panel board for 5 s to activate the winter mode The LED flashes green yellow All other functions are deactivated To deactivate the winter mode press the button on the control panel to turn off the air conditioner ...

Page 34: ...ess Clean the remote control with a slightly damp cloth from time to time We recommend using a cleaning cloth for glasses to clean the display NOTICE Beware of damage Do not clean the roof air conditioner with a high pressure cleaner Exposure to water can damage the air conditioner Do not use sharp or hard objects or cleaning agents for cleaning as these may damage the roof air conditioner To clea...

Page 35: ...r WARNING Any other maintenance work to that which is described here may only be carried out by qualified personnel who are familiar with the risks involved when handling refrigerant and air conditioning systems as well as the relevant regulations 1 1 1 1 FreshJet 2200 FreshJet 3200 9 1 2 3 A B 0 ...

Page 36: ... with a detergent solution and let it dry Put the dry filter 2 back in Put the cover 1 back on Once per year Check the profile seals Check the seal between the roof air conditioner and the roof of the vehicle for cracks and other damage Once per year Have the heat exchanger serviced Have the heat exchanger of the roof air conditioner serviced by specialist workshop Once per year Replace the carbon...

Page 37: ...oom temperature Select a lower temperature The ambient temperature is below 16 C The roof air conditioner is only designed for ambient temperatures above 16 C One of the temperature sensors is defective Contact an authorised workshop The vaporiser fan is damaged The condenser fan is damaged Low air output The air intake section is clogged up Remove any leaves and other dirt from the ventilation gr...

Page 38: ... on No supply voltage 230 Vw connected Check the power supply The voltage is too low under 200 Vw The voltage converter is defective Contact an authorised workshop One of the temperature sensors is defective The electrical fuse of the power supply is too low Check the electrical fuse of the power supply Roof air conditioner does not switch off One of the temperature sensors is defective Contact an...

Page 39: ...s place All product components must be disposed of preferably recycled in compliance with statutory legislation in the country in which disposal takes place For correct disposal the appliance must be consigned to an authorised waste disposal company to ensure that all recyclable components are reused and the remaining materials are processed properly During installation ensure the room has adequat...

Page 40: ...is present Discharge of refrigerant into the atmosphere is against the law Severe penalties apply M If you wish to finally dispose of the product ask your local recycling centre or specialist dealer for details about how to do this in accordance with the applicable disposal regulations Dispose of the product at an official waste disposal facility in accordance with the applicable recycling or disp...

Page 41: ...e 230 Vw 50 Hz Power consumption in cooling mode 4 1 A 6 3 A Power consumption in heating mode 5 2 A 5 6 A Operating temperature range 0 C to 52 C Refrigerant R 407c R 410a Refrigerant quantity 520 g 735 g CO2 equivalent 0 92248 t 1 53468 t Global warming potential GWP 1774 2088 Blower 4 blower levels 1 Automatic mode Protection class IPX4 Max volume of space in the vehicle with insulated walls 25...

Page 42: ...EN Technical data FreshJet 42 FreshJet 2200 787 254 533 25 60 562 225 47 535 480 a 980 703 277 248 25 60 650 480 535 FreshJet 3200 b ...

Page 43: ......

Page 44: ...kland 1642 64 9 622 1490 64 9 622 1573 Mail customerservices dometic co nz NORWAY Dometic Norway AS Østerøyveien 46 N 3232 Sandefjord 47 33428450 47 33428459 Mail firmapost dometic no POLAND Dometic Poland Sp z o o Ul Puławska 435A PL 02 801 Warszawa 48 22 414 3200 48 22 414 3201 Mail info dometic pl PORTUGAL Dometic Spain S L Branch Office em Portugal Rot de São Gonçalo nº 1 Esc 12 2775 399 Carca...

Reviews: