EN
CRX
Troubleshooting
33
Compressor is not running (connected to AC supply)
Poor cooling, increase in interior temperature
Unusual noises
Problem
Possible cause
Remedy
No voltage
Connection supply line interrupted
Establish a connection
Main switch faulty (if installed)
Replace the main switch
Additional supply line fuse has blown
(if installed)
Replace the supply line
fuse
Voltage is present but
the compressor doesn't
run
Ambient temperature too high
–
Insufficient ventilation
Move the refrigerator to
another location
Condenser is dirty
Clean the condenser
Electric circuit between
the pins in the
compressor interrupted
Defective compressor
Replace the compressor
Problem
Possible cause
Remedy
Compressor runs for a
long time/continuously
Ambient temperature too high
–
Insufficient ventilation
Move the refrigerator to
another location
Condenser is dirty
Clean the condenser
Faulty fan
Replace the fan
Compressor does not
run often
Battery capacity exhausted
Charge the battery
Problem
Possible cause
Remedy
Loud humming
A component of the refrigerant circuit
cannot move freely (touching the
wall)
Bend the component
carefully away from the
obstruction
There is a foreign object stuck
between the cooling unit and the wall
Remove the foreign
object
Fan noise
–
CRX50-65-80-110-140-IO-16s.book Seite 33 Donnerstag, 1. Dezember 2016 2:27 14
Summary of Contents for COOLMATIC
Page 2: ...CRX 2 CRX 50 1 2 3 5 4 6 7 1 1 2 3 5 4 6 7 CRX 65 2...
Page 3: ...CRX 3 1 2 3 5 4 6 7 CRX 80 3 4 1 2 3 5 4 6 7 CRX 110...
Page 4: ...CRX 4 5 5 1 2 3 5 4 6 7 CRX 140 1 2 3 4 6 5 7 8 6 CRX50 CRX65 CRX80...
Page 6: ...CRX 6 2 1 9 1 2 0...
Page 7: ...CRX 7 a b c...
Page 8: ...CRX 8 mm l m 12V 24V 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 0 2 6 10 14 d 1 rt sw e...
Page 9: ...CRX 9 1 2 f 12 V 24 V 10 A 2 1 rt sw rt sw sw 100 240 V g 1 Vent Lock h...
Page 10: ...CRX 10 380 534 500 CRX 50 i CRX 65 448 525 545 j CRX 80 475 640 528 k...
Page 11: ...CRX 11 CRX 110 520 745 558 l CRX 140 525 812 620 m...
Page 296: ...RU CRX 296 1 297 2 297 3 301 4 301 5 302 6 302 7 305 8 310 9 316 10 316 11 317 12 317 13 323...
Page 297: ...RU CRX 297 1 D A I 2...
Page 298: ...RU CRX 298 2 1 D 8 8...
Page 299: ...RU CRX 299 A 2 2 D...
Page 300: ...RU CRX 300 A...
Page 304: ...RU CRX 304 6 2 6 4 7 5 1 2 3 4 5 6 7 CRX50 CRX65 CRX80 CRX110ACDC CRX140ACDC 8...
Page 305: ...RU CRX 305 7 7 1 D A 30 8 5 16 C 43 C CRX110ACDC CRX140ACDC 10 C 16 C...
Page 307: ...RU CRX 307 7 4 306 314 0 2 6 0 1 6 0 2 6 7 5 a 7 c 7 7 6 A 12 24...
Page 308: ...RU CRX 308 d 8 d 8 A 15 A 12 7 5 A 24 e 1 8 e rt 8 e sw 8 12 24 10 4 22 8 11 7 24 2 l...
Page 310: ...RU CRX 310 8 A I 316...
Page 311: ...RU CRX 311 8 1 5 8 2 I 8 8 3 I 16 20 C 2...
Page 312: ...RU CRX 312 8 4 CRX50 CRX65 CRX80 A 3 3 8 5 CRX110ACDC CRX140ACDC 16 C 3 3...
Page 313: ...RU CRX 313 8 6 A I...
Page 314: ...RU CRX 314 8 7 A 8 8 A h 1 9 Lock Vent...
Page 316: ...RU CRX 316 9 A 10...
Page 317: ...RU CRX 317 11 M 12 6 2 4 7 2 5...
Page 318: ...RU CRX 318 CRX50 CRX65 CRX80 1 2 1 A 3 5 4 1850 1 5...
Page 319: ...RU CRX 319 CRX110 CRX140 1 2 1 A 3 5 4 1850 1 5...
Page 320: ...RU CRX 320 U 0 U U U U d 8 U U U U U...
Page 321: ...RU CRX 321...
Page 322: ...RU CRX 322...
Page 324: ...RU CRX 324 T 90 30 11 25 C5H10 R134a 38 42 48 i 10 j 10 k 10 17 19 21 CRX50 CRX65 CRX80 E4...
Page 326: ...RU CRX 326 T 90 30 11 25 C5H10 R134a 47 50 l 11 m 11 27 6 30 6 CRX110 CRX140 E4...