background image

EN

Operation

CoolFreeze

16

7.6

Setting the temperature

CDF26

Press the “SET” button once.

Use the “+” and “–” buttons to set the cooling temperature.

The set cooling temperature then appears in the display for a few seconds. The 
display flashes several times before it returns to the current temperature.

CDF36, CDF46

Press the “SET” button once.

Use the “ADJUST” button to set the cooling temperature.

The set cooling temperature then appears in the display for a few seconds. The 
display flashes several times before it returns to the current temperature.

7.7

Selecting the temperature unit

CDF26

You can switch the temperature display between Celsius and  Fahrenheit. To do this, 
proceed as follows:

Switch on the cooler.

Press the “SET” button twice.

Use the “+” and “–” buttons to set the cooling temperature.

The set temperature unit then appears in the display for a few seconds. The dis-
play flashes several times before it returns to the current temperature.

CDF36, CDF46

You can switch the temperature display between Celsius and Fahrenheit. To do this, 
proceed as follows:

Switch on the cooler.

Press the “SET” button twice.

Use the “ADJUST” button to set the Celsius or Fahrenheit temperature unit.

CDF18-26-36-46--O-16s.book  Seite 16  Montag, 7. November 2016  2:13 14

Autogoods “130”

130.com.ua

Summary of Contents for CDF 36

Page 1: ...ries SECURITY SYSTEMS Car alarms Bike alarms Mechanical blockers Immobilizers Sensors Accessories OPTIC AND LIGHT Xenon Bixenon Lamps LED Stroboscopes Optic and Headlights Washers Light rain sensors A...

Page 2: ...CDF18 CDF26 CDF36 CDF46 Compressor Cooler Operating manual 4 EN COOLING BOXES COOLFREEZE CDF18 26 36 46 O 16s book Seite 1 Montag 7 November 2016 2 13 14 Autogoods 130 1 3 0 c o m u a...

Page 3: ...FREEZE ERROR POWER HIGH 0 LOW TEMPERATURE BATTERY MONITOR 1 CDF18 2 3 4 5 2 12 24V DC CDF26 CDF36 CDF46 3 ERROR POWER CDF26 1 3 4 5 6 7 2 4 CDF18 26 36 46 O 16s book Seite 2 Montag 7 November 2016 2 1...

Page 4: ...CoolFreeze 3 ERROR POWER CDF36 CDF46 1 3 4 5 6 2 5 1 6 1 2 3 4 5 6 7 CDF26 CDF36 CDF46 1 2 8 CDF18 26 36 46 O 16s book Seite 3 Montag 7 November 2016 2 13 14 Autogoods 130 1 3 0 c o m u a...

Page 5: ...anufacturer cannot be held liable for damage resulting from improper usage or incorrect operation Contents 1 Explanation of symbols 5 2 Safety instructions 5 3 Scope of delivery 7 4 Accessories 7 5 In...

Page 6: ...ory or mental capacities or a lack of experience and or knowledge providing they are supervised or have been taught how to use the device safely and are aware of the resulting risks Cleaning and user...

Page 7: ...he socket by the cable Disconnect the cooler and other power consuming devices from the battery before connecting the quick charging device Disconnect the cooler or switch it off when you turn off the...

Page 8: ...t covered Do not fill the inner container with ice or fluid Never immerse the device in water Protect the device and the cable against heat and moisture 3 Scope of delivery fig 1 page 2 shows the scop...

Page 9: ...ree insulation and powerful compressor ensure especially fast cooling The cooler is designed for mobile use When used on boats the cooler can be withstand a constant heel inclination of 30 An integrat...

Page 10: ...Device is switched on and ready for operation LED is lit yellow Set temperature has been reached 3 ERROR LED flashes red Switched on device is not ready for operation 4 BATTERY MONITOR Switch on devic...

Page 11: ...Display switched off auto matically due to low battery voltage 3 ERROR LED flashes red Device is switched on but not ready for operation 4 SET Selects the input mode Temperature setting Celsius or Fah...

Page 12: ...ange Display switched off automatically due to low battery voltage 3 ERROR LED flashes red Device is switched on but not ready for operation 4 SET Selects the input mode Temperature setting Celsius or...

Page 13: ...ed with an electronic system to prevent the polarityreversal Thisprotectsthecooleragainstshort circuitingwhenconnectingto a battery Plug the 12 24 V connection cable fig 1 2 page 2 into the DC voltage...

Page 14: ...battery is recharged Battery monitor mode LOW HIGH Switch off voltage at 12 V 10 2 V 0 3 V 11 2 V 0 3 V Restart voltage at 12 V 11 2 V 0 3 V 12 2 V 0 3 V Switch off voltage at 24 V 22 0 V 0 3 V 23 9...

Page 15: ...Make sure that the ventilation slots are not covered and that the heated air can dissipate Close the cooler see chapter Connecting the cooler on page 12 A Locking the cooler Close the lid Press the l...

Page 16: ...lit green The display switches on and shows the current cooling temperature The cooler starts cooling the interior CDF18 Switching off the cooler Empty the cooler To Switch the cooler off Slide the sl...

Page 17: ...erature 7 7 Selecting the temperature unit CDF26 You can switch the temperature display between Celsius and Fahrenheit To do this proceed as follows Switch on the cooler Press the SET button twice Use...

Page 18: ...ut of the upper half of the housing fig 7 1 page 3 Carefully raise the upper half of the housing from the lower fig 7 6 page 3 half Take out the contact pin fig 7 3 page 3 Replace the defective fuse f...

Page 19: ...back of the instruction manual for the addresses or your retailer For repair and guarantee processing please include the following documents when you send in the device A copy of the receipt with pur...

Page 20: ...ool plug is inserted ERROR LED flashes Battery voltage is too low Test the battery and charge it as needed When operating from the DC power socket The ignition is on and the device is not work ing and...

Page 21: ...Rated current 12 Vg 3 5 A 5 0 A 24 Vg 1 9 A 2 5 A Cooling capacity 10 C to 18 C Climate class N or T Ambient temperature 16 C 43 C Dimensions WxHxD in mm 465 x 414 x 300 550 x 425 x 260 Weight 9 5 kg...

Page 22: ...24 Vg 2 5 A 2 5 A Cooling capacity 10 C to 15 C Climate class N or T Ambient temperature 16 C 43 C Dimensions WxHxD in mm 560 x 380 x 340 560 x 475 x 340 Weight 12 5 kg 13 7 kg Tests Certification NO...

Reviews: