MT MPP170, MT MPP260, MT MPP 440
Operation
EN
23
DIP switch
position
Desired charging
program
DIP switch
position
Desired charging
program
Lead-acid batteries
(14.4 V) or
AGM batteries (14.4 V)
(fig.
• U1: 14.40 V
(0.5 – 4 h)
• U2: 13.45 V
Lead gel batteries
(14.3 V)
(fig.
• U1: 14.30 V
(1.5 – 6 h)
• U2: 13.80 V
AGM batteries (14.7 V)
(fig.
• U1: 14.70 V
(0.5 – 3 h)
• U2: 13.50 V
LiFePO4 batteries
(13.9 V)
(fig.
• U1: 13.90 V
(0.5 – 1.5 h)
• U2: 13.90 V
LiFePO4 batteries
(14.4 V)
(fig.
• U1: 14.40 V
(0.3 – 1 h)
• U2: 13.8 V
LiFePO4 batteries
(14.2 V)
(fig.
• U1: 14.20 V (0.5 h)
• U2: 13.60 V
LiFePO4 batteries
(14.7 V)
(fig.
• U1: 14.70 V
(0.3 – 1 h)
• U2: 13.70 V