4
EN
General Information
Universal Air Conditioning Unit
WARNING: EXPLOSION HAZARD . Failure to
obey these warnings could result in death or
serious injury .
• Avoid puncturing or breaking the unit or any of the
unit’s tubing.
• When installing this equipment, always observe
precautions described in the literature, tags, and
labels attached to the unit.
• Follow all safety codes.
• Wear safety glasses and work gloves and place a fire
extinguisher close to the work area.
• Failure to follow these guidelines could result in a
system rupture that would release high-pressure gas
and airborne shrapnel.
NOTICE:
Improper installation or misunderstood
operating procedures can result in unsatisfactory
performance and/or premature failure of these units.
2 General Information
This section provides general information about
the refrigerant used in this system and the general
information regarding the unit.
The images used in this document are for reference
purposes only. Components and component locations
may vary according to specific product models.
Measurements may vary ±0.38 in. (10 mm).
2 .1 R-410A Reference Information
This section provides information regarding the type of
refrigerant used in this air conditioning unit.
• This system uses R-410A refrigerant.
• R-410A is an environmentally safe hydrofluorocarbon
(HFC) refrigerant.
• R-410A refrigerant operates at a higher pressure
than R-22. Ensure that the servicing equipment and
replacement components used are designed to
operate with R-410A.
I
Refer to the service manual for this unit for more
information on R-410A refrigerant.
2 .2 Q3 Control Standard Features
This list provides the functions that are standard for the
Q3 control when used with the ASCDU15HV 1161.
• 115 Volt, 60 Hz AC power supply
• User-friendly, four-button display panel
• Option to display temperature in degrees Fahrenheit
or Celsius
• Programmable functions
• Non-Volatile Memory (NVM) requires no backup
power
• Switch inputs for high/low refrigerant pressure
• Time function (away mode)
• Anti-icing cycle prevents evaporator icing
• Programmable fan operation
• Programmable display brightness
• Air-filter cleaning or replacement timer
• Low-voltage monitor
I
An optional outside temperature sensor is available
for this unit.
2 .3 Product Data Plate
MFG NO.
710015113
921053890
9600005548
DESCRIPTION
CAP. (BTU)
VOLTAGE/HERTZ
PHASE
MAX. FUSE
MIN. FUSE
FLA. COOL
FLA. HEAT
ASCDU15HV1161 2.5KW 115/60/1
15000
FAN
5.92
OPERATE AT 60HZ ONLY
VOLTAGE - 104 MIN. 126 MAX. FREQ-57-63HZ.
L.R.A.
69.8
tCO2e
2.25
GWP
2088
OIL
DIAGRAM
PATENT(S):
Assembled in USA
DPEV02
2000 NORTH ANDREWS AVE
POMPANO BEACH, FL 33069 USA
954-973-2477 WWW.DOMETIC.COM
DOF700
POE
340494
REFRIG. --- OZ/GRAMS
R410A 38/1078
115*
1
40
30
25.7
24.3
SHOP ORDER
PROD NO.
SERIAL NO.
SKU NO.
w
q
1
Data Plate
q
Amp Draw Cool and Heat
w
Weigh-In Charge