Recommended mounting location for caravans

Recommended mounting location for pop-top caravans

4

 300 mm

5

DRS-IOM.book  Seite 10  Freitag, 9. August 2019  9:48 09

Summary of Contents for 9600025579

Page 1: ...DRS Dust Reduction System Installation and Operating Manual EN WINDOWS DOORS LIGHTS OTHER DRS IOM book Seite 1 Freitag 9 August 2019 9 48 09...

Page 2: ...DRS IOM book Seite 2 Freitag 9 August 2019 9 48 09...

Page 3: ...livery 5 4 Intended use 6 5 Technical description 6 6 Installation 9 7 Regular maintenance 16 8 Warranty 20 9 Disposal 21 10 Technical data 21 1 Explanation of symbols A WARNING Safety instruction Ind...

Page 4: ...roof air conditioner 2 1 General safety WARNING Only use the device as intended Do not make any alterations or conversions to the device CAUTION The dust reduction system must be installed securely so...

Page 5: ...oof flange 3 1 Bottom ceiling flange with ceiling cover and blocking plate 4 10G x 80 mm self tapping screws 4 10G x 60 mm self tapping screws 4 10G x 34 mm self tapping screws 16 10 mm long spacer 4...

Page 6: ...e DRS can also be installed on horse floats to pro vide a source of clean filtered air for horses The DRS works from vehicle speeds of 25 km h and above The DRS is assisted by airflow so it becomes mo...

Page 7: ...s designed to slide into a groove in front of the main filter and rest on the locating tab shown fig 3 page 8 To fit the blocker plate open the interior ceiling cover by pulling on the edge marked PUL...

Page 8: ...ical description DRS 8 Closetheinteriorceiling coverby rotatingthe coverupwardsand pushing gently until the magnets engage to hold the cover closed 1 2 4 3 3 DRS IOM book Seite 8 Freitag 9 August 2019...

Page 9: ...the device and put the safety of the user at risk The manufacturer assumes no liability for malfunctions and for the safety of the DRS especially for injury and or damage to property if the DRS is not...

Page 10: ...EN Installation DRS 10 Recommended mounting location for caravans Recommended mounting location for pop top caravans 4 300 mm 5 DRS IOM book Seite 10 Freitag 9 August 2019 9 48 09...

Page 11: ...ports Mark the position and size of the opening A 285 x 285 mm opening is recom mended but can be as large as 400 x 400 mm Drill out the corners A Carefully cut out the opening on the roof using a jig...

Page 12: ...eal will easily stretch to bend around the cor ners while staying flat Ensure the arrows on the top surface are pointing to the front of the caravan Position the top roof flange centrally within the o...

Page 13: ...suitable orientation for the hinged cover for easy access hinges can face either the front or rear of the cara van Frominsidethecaravan checkthespacerlengthrequiredbyholdingthebottom roof flange in pl...

Page 14: ...f flange and slide the spacer over the protruding part of the screw so that the spacer will be fitted between the bottom roof flange and the top roof flange Roof thickness mm Screw 10G x 60 mm Screw 1...

Page 15: ...this occurs increase the total length of the sleeves by 5 mm or unscrew by half a turn If there is no deformation sleeves too long then there will be insufficient clamping of the joint and the sleeves...

Page 16: ...by magnets on the opposite side Open the cover by pulling down on the side marked PULL HERE TO OPEN Remove the filter holder by pushing the two tabs inwards and pulling down on the filter holder gent...

Page 17: ...emove excess dust Replace filter if there are signs of damage filter media becomes furry or separates Driving condition Filter inspection interval Filter replacement interval Sealed roads 2000 km 10 0...

Page 18: ...d debris Any debris in the filter or filter holder can be removed by following the steps in chapter Changing the main filter on page 16 If debris are located between the front grille and the filter ma...

Page 19: ...n from harmful gases The foam should be checked at least every 6 months or more frequently if travelling in very dusty conditions the check interval should match the interval recommended for the main...

Page 20: ...ing on the housing Angle the rear edge upwards until the clip is pushed fully upwards 8 Warranty The warranty period is two years If the product is defective please contact the ser vice partner Our ex...

Page 21: ...ct ask your local recycling centre or spe cialist dealer for details about how to do this in accordance with the applicable disposal regulations 10 Technical data DRS SKU Dust Reduction System 9600025...

Page 22: ...EN Technical data DRS 22 Dimensional tolerance 3 mm 482 282 400 444 245 95 96 282 473 g DRS IOM book Seite 22 Freitag 9 August 2019 9 48 09...

Page 23: ...EN DRS Technical data 23 Dimensional tolerance 3 mm 275 436 12 28 h DRS IOM book Seite 23 Freitag 9 August 2019 9 48 09...

Page 24: ...metic 0 0 s YOUR LOCAL DEALER dometic com dealer YOUR LOCAL SUPPORT dometic com contact dometic com 1 01 1 0 4 0 1 1 2 2 1 2 9 0 DOMETIC GROUP AB 3E 0 1 4 4445102874 08 2019 DRS IOM book Seite 24 Frei...