background image

EN

TCX14, TCX21, TCX35

Operation

11

6.3

Using the battery monitor

The device is equipped with a multi-level battery monitor that protects your vehicle 
battery against excessive discharging when the device is connected to the on-board 
DC supply. 

If the cooler is operated when the vehicle ignition is switched off, the cooler switches 
off automatically as soon as the supply voltage falls below a set level. The cooler will 
switch back on once the battery has been recharged to the restart voltage level. 

A

In “HIGH” mode, the battery monitor responds faster than at the level “LOW” (see 
the following table).

Slide the switch (fig.

1

4, page 2) to the appropriate setting in order to select 

the battery monitor mode.

Slide the switch (fig.

1

4, page 2) to „OFF“ in order to deactivate the battery 

monitor mode.

I

6.4

Opening the cooler

TCX35 only

: Unlock the cooling device (fig.

2

, page 2).

Open the cooling device.

NOTICE! Danger of damage!

When switched off by the battery monitor, the battery will no longer be 
fully charged. Avoid starting repeatedly or operating current consumers 
without longer charging phases. Ensure that the battery is recharged.

Battery monitor mode

LOW

HIGH

Switch-off voltage at 12 V

10.1 V

11.7 V

Restart-voltage at 12 V

11.5 V

13.1 V

Switch-off voltage at 24 V

21.5 V

24.6 V

Restart voltage at 24 V

23.0 V

26.2 V

NOTE 

When the cooler is supplied by the starter battery, select the battery 
monitor mode “HIGH”. If the cooler is connected to a supply battery, 
the battery monitor mode “LOW” will suffice.

TCX14-TCX35-OPM-EMEA16.book  Seite 11  Montag, 6. Mai 2019  1:17 13

Summary of Contents for 9600014289

Page 1: ...TCX14 TCX21 TCX35 Thermoelectric cooler Operating manual 5 EN MOBILE COOLING TCX14 TCX35 OPM EMEA16 book Seite 1 Montag 6 Mai 2019 1 17 13 TCX SERIES...

Page 2: ...TCX14 TCX21 TCX35 2 3 2 1 4 1 2 1 2 3 4 5 6 3 TCX14 TCX35 OPM EMEA16 book Seite 2 Montag 6 Mai 2019 1 17 13...

Page 3: ...TCX14 TCX21 TCX35 3 4 12 24 Vg 5 2 1 A B C 1 1 2 2 1 6 TCX14 TCX35 OPM EMEA16 book Seite 3 Montag 6 Mai 2019 1 17 13...

Page 4: ...CX21 TCX35 4 1 5 2 L 450 323 250 303 208 201 260 328 7 1 5 2 L 550 340 460 376 265 350 TCX14 TCX21 TCX35 1 5 2 L 450 319 250 420 303 198 208 352 TCX14 TCX35 OPM EMEA16 book Seite 4 Montag 6 Mai 2019 1...

Page 5: ...ols 5 2 Safety notes 6 3 Scope of delivery 9 4 Use as intended 9 5 Technical description 9 6 Operation 10 7 Cleaning and servicing 13 8 Disposal 14 9 Troubleshooting 14 10 Technical data 15 1 Explanat...

Page 6: ...ncludingchildren with reducedphysical sensoryormentalcapabilities orlack ofexperience and knowledge unless they have been given supervision or instruc tion concerning use of the device by a person res...

Page 7: ...o a DC outlet Disconnect the cooling device and other power consuming devices from the battery before connecting a quick charging device If the cooling device is connected to a DC outlet Disconnect th...

Page 8: ...vices inside the cooling device unless they are recommended by the manufacturer for the purpose Do not place the cooling device near naked flames or other heat sources heaters direct sunlight gas oven...

Page 9: ...t will automatically switch over to the energy save mode In this mode only the energy which is required to reach the temperature inside the box is consumed The cooling device is a low wear thermo elec...

Page 10: ...ersal Thisprotectsthecooleragainstshort circuitingwhenconnectingto a battery NOTE Before you put the new cooling device into operation you should clean it inside and outside with a damp cloth for hygi...

Page 11: ...attery monitor mode Slide the switch fig 1 4 page 2 to OFF in order to deactivate the battery monitor mode I 6 4 Opening the cooler TCX35 only Unlock the cooling device fig 2 page 2 Open the cooling d...

Page 12: ...to finish the cooling or heating process press the button P When you stop using the cooling device disconnect it from the mains 6 7 Select temperature The set temperature status display fig 3 5 page 2...

Page 13: ...a damp cloth NOTE The following temperature indications are subject to tolerances and are dependent on the measuring position Status display fig 3 5 page 2 Interior temperature Cooling 7 illuminated L...

Page 14: ...in your vehicle The ignition must be switched on in most vehicles to apply current to the DC power socket The ignition is switched on and the cooling device does not work The DC power socket is dirty...

Page 15: ...the inner ventilator is defective The thermo electric element is defective The integrated power unit is defective TCX14 TCX21 TCX35 Input voltage 12 24 Vg 220 240 Vw Power input 46 W 12 Vg 50 W 24 Vg...

Page 16: ...num 77 kWh annum Gross capacity 14 l 21 l 35 l Usable capacity 13 5 l 20 l 33 l Climate class T Ambient temperature 16 C to 43 C Noise emission 41 dB A Weight 5 8 kg 7 3 kg 10 6 kg Inspection Certific...

Page 17: ......

Reviews: