Dometic 57908.321 Installation Instructions Manual Download Page 4

4

INSTALLATION INSTRUCTIONS DUCTED  CCC

MODEL

NOMINAL

ELECTRICAL

COMPRESSOR

COMPRESSOR

FAN MOTOR

FAN MOTOR

S

C

F

M

-H

IG

H

T

O

T

A

L

REFRIGERANT

MINIMUM

A

C

 CIRCUIT

INST

ALLED

 MINIMUM

NO.

CAP

A

C

IT

Y

R

A

TING

R

A

TED LOAD

LOCKED

R

A

TED LOAD

LOCKED

SPEED

ST

A

TIC

R-22 (OZ)

WIRE SIZE*

PROTECTION

WEIGHT

GENERA

T

O

R

(BTU/HR)

AMPS

ROTOR

AMPS

R

O

T

O

R

MAX/MIN

MAX/MIN

*** USER

(POUNDS)

SIZE**

COOLING

AMPS

AMPS

“ W

. C

.

SUPPLIED

1

 UNIT/ 2 UNITS

5

9

5

1

6

.3

3

6

15,000

12.7

60.0

2

.0

5

.6

325 / 250

0.40 / 1.10

29.0

2

0

 A

m

p

94

3.5 KW / 5.0 KW

5

9

5

1

6

.5

0

1

15,000

12.9

71.0

2

.5

6

.0

325 / 250

0.40 / 1.10

31.0

2

0

 A

m

p

94

3.5 KW / 5.0 KW

5

9

5

1

6

.5

0

6

15,000

12.9

71.0

2

.5

6

.0

325 / 250

0.40 / 1.10

31.0

2

0

 A

m

p

94

3.5 KW / 5.0 KW

5

9

5

1

6

.5

3

1

15,000

11

.5

50.0

2

.5

5

.8

325 / 250

0.40 / 1.10

26.5

2

0

 A

m

p

94

3.5 KW / 5.0 KW

5

9

5

1

6

.5

3

6

15,000

11

.5

50.0

2

.5

5

.8

325 / 250

0.40 / 1.10

29

2

0

 A

m

p

94

3.5 KW / 5.0 KW

5

9

5

1

6

.6

0

1

15,000

12.9

77.0

2

.5

6

.0

350 / 250

0.40 / 1.10

31.0

2

0

 A

m

p

1

0

2

3.5 KW / 5.0 KW

5

9

5

1

6

.6

0

3

15,000

12.3

77.0

2

.0

5

.6

325 / 250

0.40 / 1.10

29.5

2

0

 A

m

p

1

0

2

3.5 KW / 5.0 KW

5

9

5

1

6

.6

0

6

15,000

12.9

71.0

2

.5

6

.0

325 / 250

0.40 / 1.10

31.0

2

0

 A

m

p

94

3.5 KW / 5.0 KW

5

9

5

1

6

.6

3

1

15,000

12.3

77.0

2

.0

5

.6

325 / 250

0.40 / 1.10

29.5

2

0

 A

m

p

1

0

4

3.5 KW / 5.0 KW

5

9

5

2

8

.6

0

1

N

/A

6

.0

45.6

2

.0

5

.6

325 / 250

0.40 / 1.10

16.5

1

5

 A

m

p

92

3.5 KW / 5.0 KW

5

9

5

2

9

.5

3

1

N

/A

6

.9

49.0

2

.0

5

.6

325 / 250

0.40 / 1.10

18.5

1

5

 A

m

p

94

3.5 KW / 5.0 KW

5

9

5

2

9

.6

0

1

N

/A

8

.0

48.3

2

.0

5

.6

325 / 250

0.40 / 1.10

19.0

1

5

 A

m

p

94

3.5 KW / 5.0 KW

5

9

5

2

9

.6

3

1

N

/A

8

.0

48.3

2

.0

5

.6

325 / 250

0.40 / 1.10

19.0

1

5

 A

m

p

94

3.5 KW / 5.0 KW

5

9

5

3

0

.5

3

1

N

/A

7

.8

53.0

2

.0

5

.6

325 / 250

0.40 / 1.10

19.0

1

5

 A

m

p

94

3.5 KW / 5.0 KW

5

9

5

3

0

.5

3

2

N

/A

8

.0

53.0

2

.5

5

.8

325 / 250

0.40 / 1.10

18.5

1

5

 A

m

p

94

3.5 KW / 5.0 KW

5

9

5

3

0

.5

3

6

N

/A

7

.8

53.0

2

.0

5

.6

325 / 250

0.40 / 1.10

19.0

1

5

 A

m

p

94

3.5 KW / 5.0 KW

5

9

5

3

0

.6

0

1

N

/A

8

.0

48.3

2

.0

5

.6

325 / 250

0.40 / 1.10

19.0

1

5

 A

m

p

93

3.5 KW / 5.0 KW

5

9

5

3

0

.6

3

1

N

/A

8

.0

48.3

2

.0

5

.6

325 / 250

0.40 / 1.10

19.0

1

5

 A

m

p

94

3.5 KW / 5.0 KW

5

9

5

3

0

.6

3

2

N

/A

8

.5

48.3

2

.5

5

.8

325 / 250

0.40 / 1.10

18.0

1

5

 A

m

p

94

3.5 KW / 5.0 KW

600312.321

11,000

9

.5

53.0

3

.1

8

.8

335 / 250

0.12 / 0.65

16.5

2

0

 A

m

p

95

2.5 KW /4.0 KW

600312.421

11,000

10.7

50.0

3

.1

8

.8

335 / 250

0.12 / 0.65

16.0

2

0

 A

m

p

1

0

1

2.5 KW / 4.0 KW

600315.321

13,500

12.4

60.0

3

.1

8

.8

335 / 250

0.12 / 0.65

15.5

2

0

 A

m

p

96

3.5 KW / 5.0 KW

600315.421

13,500

11

.5

50.0

3

.1

8

.8

335 / 250

0.12 / 0.65

17.0

2

0

 A

m

p

1

0

2

3.5 KW / 5.0 KW

630035.321

13,500

12.4

60.0

3

.1

8

.8

335 / 250

0.12 / 0.65

24.5

2

0

 A

m

p

1

0

1

3.5 KW / 5.0 KW

630035.421

13.500

11

.0

50.0

3

.1

8

.8

335 / 250

0.12 / 0.65

19.5

2

0

 A

m

p

1

0

2

3.5 KW / 5.0 KW

SPECIFICA

TIONS

115V

AC,

60 HZ., 1PH.

12 AWG

Copper

up to 24’

*

For wire lengths over 24 ft. consult the National Electric Code for proper sizing.

**

Dometic Corporation gives 

GENERAL

 guidelines for generator requirements. These guidelines come from experiences people have had in actual applications

When sizing the generator

, the tot

al power usage of your recreational vehicle must be considered. Keep in mind generators lose 

power at high altitudes and

from lack of maintenance.

**

*

CIRCUIT PROTECTION: Time Delay Fuse or HACR Circuit Breakers  Required.

Summary of Contents for 57908.321

Page 1: ...ic Control Kit Ducted 59136 531 59136 536 59136 621 59136 631 59516 303 59516 331 59516 336 59516 501 59516 531 59516 536 59516 601 59530 632 600312 321 600315 326 600312 421 600315 321 600315 421 630...

Page 2: ...erature For a more permanent solution to high heat gain accesso ries like A E outdoor patio and window awnings will reduce heat gain by removing the direct sun They also add a nice area to enjoy compa...

Page 3: ...1 3 62 0 2 5 5 8 325 250 0 55 0 90 16 0 20 Amp 94 3 5 KW 5 0 KW 57915 621 13 500 11 0 54 4 2 5 5 8 325 250 0 55 0 90 16 0 20 Amp 94 3 5 KW 5 0 KW 57915 622 13 500 11 0 54 4 2 5 5 8 325 250 0 55 0 90 1...

Page 4: ...31 N A 8 0 48 3 2 0 5 6 325 250 0 40 1 10 19 0 15 Amp 94 3 5 KW 5 0 KW 59530 531 N A 7 8 53 0 2 0 5 6 325 250 0 40 1 10 19 0 15 Amp 94 3 5 KW 5 0 KW 59530 532 N A 8 0 53 0 2 5 5 8 325 250 0 40 1 10 18...

Page 5: ...front to back and centered from side to side B For Two Unit Installations Install one air conditioner heat pump one third and one airconditioner heatpumptwo thirdsfromfrontofRVand centered from side t...

Page 6: ...ductwork will not collapse or bend during and after the installation Dometic Corporation will not be liable for roof struc tural or ceiling damage due to improperly in sulated sealed or collapsed duc...

Page 7: ...be electrical wiring between the roof and the ceiling Disconnect 115 volt AC power cord and the positive 12 volt DC terminal at the supply battery Failure to fol low this instruction may create a sho...

Page 8: ...Duct Size And Requirements For 3105007 XXX And 3105935 XXX Return Air Cover Duct Size And Requirements For 3308120 XXX Genesis Air Filtration System Total Outlet Air Area Minimum 21 0 Sq In Total Outl...

Page 9: ...dedicated 12VDC supply line 18 to 22 AWG from the RV s converter or battery to the roof opening a This supply line must be located in the front portion of the 14 1 4 x 14 1 4 1 8 opening b Make sure t...

Page 10: ...V AC REAR A C 115V AC REAR A C 4 CONDUCTOR CONTROL CABLE 4 CONDUCTOR CONTROL CABLE 115V AC FRONT A C 115V AC FRONT A C FURNACE 2 WIRES FURNACE 2 WIRES DOMETIC COMFORT CONTROL CENTER DOMETIC COMFORT CO...

Page 11: ...f the air conditioner and pull the unit electrical cord down for later installation See FIG 11 AC Power Supply Pull Electrical Cord Down Roof Gasket FIG 11 Disconnect 115 volt AC Failure to follow the...

Page 12: ...nterTM CCC cable previously terminated see Section 6 B Control Cable into one of the control cable leads out of the air conditioner Either one of the two 2 control cables can be used 6 Connect the rem...

Page 13: ...sive The foam divider should be level with the ceiling 1 4 Tear off the excess at the pre cut perforations in divider See FIG 13B 2 Peel the paper off of the foam divider and stick it in place on the...

Page 14: ...ed See FIG 16B for Brisk Air unit and Fig 17B for Penguin units FIG 15A Installing unit with 3308120 XXX Genesis Air Filtration System continued on page 15 column B FIG 16A If bolts are left loose the...

Page 15: ...luminum foil tape not supplied to seal the ends of the foam divider to the sides of the opening Make sure the area behind the flange on the ceiling template is sealed See FIG 18B FIG 18B Use Aluminum...

Page 16: ...t power be supplied to the air conditioner and check for proper operation Refer to Operating Manual or User s Guide for a description of the air conditioner operation Installing unit with 3308120 XXX...

Page 17: ...e shortened by placing the Differential dip switch in the ON position Note Setting the Differential dip switch should only be required when the installation conditions are less than desirable and is n...

Page 18: ...579 590 591 595 600 630 579 590 591 595 600 630 509 S POPLAR ST 509 S POPLAR ST LAGRANGE IN 46761 LAGRANGE IN 46761 115VAC 60Hz 1 O 115VAC 60Hz 1 O 60 HZ 1 O 60 HZ 1 O 3106515 020 USE COPPER USE COPPE...

Reviews: