14
a. Re-connect the 12 Vdc and 120 Vac power
supplies.
b. Make sure the CCC 2 thermostat is in the
OFF
mode.
c. Simultaneously press the
MODE
and
Zone
buttons. The LCD will display "Init" and all
available zones.
d. Release the
MODE
and
Zone
buttons.
e. Press the
ON/OFF
button to exit system set
up.
f. When a dip switch is turned on after initial
configuration, a system reset will need to be
done before the CCC 2 thermostat will rec-
ognize the updated selection.
2. System Checkout
a. Verify that all features of the installed sys-
tem work. See CCC 2 thermostat Operating
Instructions or User's Guide. Check the fan
mode, cooling mode, heating mode (if ap-
plicable), and furnace mode (if applicable)
operation. If the features do not work discon-
nect the 120 Vac and 12 Vdc power supplies
and verify that all wiring is correct and that
the correct dip switches have been set to the
"
ON
" position.
O. (CCC 2 System Only) Furnace /Aqua
Temperature Differential Setting
This system can be configured to operate using an ON/OFF
differential of either 1 degree F or 2 degree F. See (FIG. 26).
1. To set the differential, simultaneously press
the
PROGRAM
button and the up button
on the CCC 2 thermostat. "diF1" will appear in
the display while the buttons are pressed. See
(FIG. 26). To set the 2 degree differential, simul-
taneously press the
PROGRAM
button and the
down button. "diF2" will appear in the display
while the buttons are pressed.
FIG. 26
h. Gen Start selection - Leave in the "OFF" po-
sition.
i. Install electronic control box cover.
j. Repeat this procedure for each additional
zone.
FIG. 24
On Position
Off Position
M. Installing Return Air Cover
1.
Remove the return air grille from the return air
cover.
2. Place the return air cover up to the ceiling tem-
plate.
3. Install cover to template using six (6) supplied
#8 x 3/8″ blunt point Phillips head screws.
4.
Reinstall filter return air grille into return air cov
-
er. Align tabs with mating notches and snap into
place.
5. Install two (2) hole plugs into screw holes in
back of return air cover. See (FIG. 25).
FIG. 25
Hole Plug
Return Air
Grille
Return Air
Cover
N. (CCC 2 System Only) Reset & Checkout
1. System Reset
After setting the dip switches in the electronic
control, do a system reset.
INSTALLATION INSTRUCTONS