Important:

 These Instructions must

stay with unit. Owner read carefully.

INSTALLATION  & OPERATING

INSTRUCTIONS

Type

Supplied by Dometic

Australia contact
www.dometic.com.au

REVISION

Form No. 54-AA-MA3200CY1

Note: Air Distribution Box installation requires a #2 Phillips screwdriver 

with a 7 mm maximum diameter x 35 mm minimum length.

RECORD THIS UNIT INFORMATION 

FOR FUTURE REFERENCE:

Type Number

Product Number

Serial Number

ADB Number

ADB Serial Number

Date Purchased

This  manual  must  be  read  and 

understood  before  installation, 

adjustment,  service,  or  mainte-

nance is performed. This unit must 

be installed by a qualified service 

technician.  Modification  of  this 

product can be extremely hazard-

ous and could result in personal 

injury or property damage.

Roof Top Unit

Description

Model

Type

Use With 

Air Distribution Box

Model

3241CX51R(CALR241)
3242CX51R(CALR242)

3242CX51R

3311669.018CY2

3311669.018CY1

B3200

Heat Pump

Air Conditioner 

W/Electric Heat

B3200

3241CX51R

18, Jinhu Lu, Sanzao, Jinwan Zhuhai, China

MOBICOOL Electronic(Zhuhai)Co., Ltd

Summary of Contents for 3241CX51R

Page 1: ...er ADB Number ADB Serial Number Date Purchased This manual must be read and understood before installation adjustment service or mainte nance is performed This unit must be installed by a qualified se...

Page 2: ...AC 50 Hz 10 Amp 3 Powerwhentheunitstartsmustbeabove198VAC and the frequency must be 50 Hz at all times D The ability of the air conditioner to maintain the de sired inside temperature depends on the h...

Page 3: ...tempting to start this unit installa tion 2 The manufacturer will not be liable for any dam ages or injury incurred due to failure in following these instructions 3 The equipment shall be installed in...

Page 4: ...ay create a shock hazard causing death or severe personal injury FIG 3 Dimensions Are Nominal Dimensions Are Nominal 70 mm overall depth 635 mm 508 mm Front 76 mm 125 mm 130 mm 76 mm 362 mm x 362 mm 3...

Page 5: ...to the open ing with approved method See paragraph d above Note These power supply connections may be replaced with type Y attachments if done by qualified personal Thisunitweighsapproximately45Kilogr...

Page 6: ...arge Opening Remove Liner From Foam Tape Front FIG 7 Screw FIG 10 Start 3 Mounting Bolts By Hand Trim Duct 13 mm To 25 mm Below Ceiling Template Ceiling frame Do not Disturb the position of Mounting B...

Page 7: ...e Check that the air filters are free to be removed and replaced 13 Position ADB Walls Inside And Against End Of Tem plate Walls Raise Back End Of ADB To Ceiling While holding the box against the ceil...

Page 8: ...ling mode Auto Button Auto button If the remote control is damaged or lost pressing the Auto button will run the air If the room temperature is above 25 degrees the unit will run in cooling mode 8 FIG...

Page 9: ...etween 18 C and Press MODE button to select this function and set the 30 C Press MODE button to select ventilation mode then the Timer on mode The machine must be off FIG 15 TURBO FAN CLOCK MODE F SLE...

Page 10: ...l not start until the air within the air conditioner is 2 Blowing surplus heat function In heating mode the fan will continue to run for appro ximately 60 seconds after the OFF button is pressed 3 Def...

Page 11: ......

Page 12: ...12 ROOF MOUNT ASSEMBLY Rear Discharge Duct Ceiling Template With Metal Brackets Mounting Bolts Air Distribution Box ADB Roof Opening Duct Adapter Vents Filter s...

Page 13: ...to motor generator check to be sure motor generator is running and producing power B If Caravan connected to power supply by a land line check to be sure line is sized properly to run unit load and i...

Reviews: