EN
Mounting the mains rectifier
CoolPower MPS80
20
6
Mounting the mains rectifier
If you wish to mount the mains rectifier in a fixed position, please observe the
following mounting instructions:
Do
not
mount the device
– In wet or damp environments
– In the vicinity of combustible materials
– In areas where there is a danger of explosions
The place of installation must be well-ventilated. A ventilation system
which is at least equivalent to the air openings in the device must be
present for installations in closed housings.
The air intake on the underside or the air outlet on the back of the device
must remain clear.
The installation surface must be level and sufficiently sturdy.
➤
Secure the mains rectifier with screws through the fastening holes at the
front and the back of the device (fig.
1
2, page 3).
7
Using the mains rectifier
A
To avoid drops in voltage and therefore performance, keep the cable route
as short as possible and only disconnect it when necessary.
The cables between mains rectifier and compressor must not exceed 1 m
and must have a cross section of at least 2.5 mm²!
➤
Fit wire sleeves to the ends of wires which you wish to connect to the
mains rectifier.
➤
Ensure that the battery’s positive supply line is secured with a fuse
(fig.
2
1, page 3) of the following value:
– at 12 V
g
: 20 A
– at 24 V
g
: 10 A
The fuse must be installed as close to the battery as possible.
NOTICE!
Do not reverse the polarity. If the poles are reversed device
may overheat and be damaged.
Replace defective fuses with new ones of the same rating
(25 A).