Condensation
All annexes suffer from internal condensation if one or more of the
following conditions apply:
•
high air humidity
•
high ground moisture
•
a drop in temperature
Severe condensation can run down the inside of the roof and drip off ties,
tapes and other internal fittings and can be mistaken for leaking.
➤
Increase ventilation by opening doors and/or windows.
➤
Install a waterproof groundsheet.
Repairing a puncture in the air pole
If the air pole loses air, proceed as follows:
1. Unzip the outer sleeve holding the air pole.
2. If installed, close isolation valves.
3. Remove the air pole.
4. Deflate the air pole.
5. Unzip the protective sleeve to expose the inflatable tube.
6. Blow some air into the inflatable tube.
7. Submerge the tube in water.
8. Locate the puncture.
9. Use repair tape and repair solution to seal the hole.
10. Zip the inflatable tube back into the protective sleeve.
11. Zip the air pole back into the outer sleeve.
Disposal
➤
Place the packaging material in the appropriate recycling waste bins,
wherever possible.
➤
Consult a local recycling center or specialist dealer for details about
how to dispose of the product in accordance with the applicable dis-
posal regulations.
Warranty
The statutory warranty period applies. If the product is defective, please
contact your retailer or the manufacturer's branch in your country (see
dometic.com/dealer).
For repair and warranty processing, please include the following docu-
ments when you send in the product:
•
A copy of the receipt with purchasing date
•
A reason for the claim or description of the fault
The warranty covers manufacturing defects, materials and parts. The
warranty does not cover fading of the cover and wear and tear due to
UV radiation, misuse, accidental damage, storm damage, or permanent,
semi-permanent or commercial use. It does not cover any resulting
damage. Please contact your dealer for claims. This does not affect your
statutory rights.
Problem
Solution
Annexe only inflates with
difficulties
➤
Check that the valve is fully screwed into the air
pole.
➤
Check if the inflation tube is twisted at the
valve.This may be indicated by noise. Untwist
the inflation tube.
➤
Check that the hand pump is working.
Air poles are kinked
➤
Add more air (9 psi /0.62 bar).
Air leak
➤
Check that the valve is fully screwed into the air
pole and the ring seal is in place.
➤
Check that the cap of the valve is done up
tightly.
➤
Check for punctures, see chapter “Repairing a
puncture in the air pole” on page 5.
Water leak
➤
Check for leaky seams, damaged tapings and
moist areas.
➤
If you cannot find any leaks, see chapter “Con-
densation” on page 5.
➤
If you find any leaks, apply seam sealant.
Rip in the fabric
➤
Use repair tape to seal the fabric.
➤
Have repairs carried out by an authorized
specialist.