domat UC905 Quick Start Manual Download Page 5

 

domat UC905 

08/2018 Subject to technical changes. 

5

 

Dimensions 

UC905 

 

UC905DK 

 

All dimensions in 

mm. 

 

Safety note 

The  device  is  designed  for  monitoring  and  control  of  heating,  ventilation,  and  air 
conditioning systems. It must not be used for protection of persons against health risks 
or death, as a safety element, or in applications where its failure could lead to physical 
or  property  damage  or  environmental  damage.  All  risks  related  to  device  operation 
must  be  considered  together  with  design,  installation,  and  operation  of  the  entire 
control system which the device is part of.

 

 

 

Summary of Contents for UC905

Page 1: ...oncetration in the room air temperature correction setpoint by a knob and required operation mode which is set by a short push or in the menu Data is transmitted to the room controller The main controller FCR015 may send to the unit other data heating cooling mode fan stage day night standby mode etc which are displayed on the LCD display Connect the room unit to FCR015 over a 4 core cable the mos...

Page 2: ...nsions 90x115x30 mm Ambient temperature External conditions 5 45 C 5 95 relative humidity non condensing gases and chemically non aggressive conditions according to EN 60721 3 3 climatic class 3K5 Storage 5 45 C 5 95 relative humidity non condensing gases and chemically non aggressive conditions according to EN 60721 3 1 climatic class 1K3 Standards conformity EMC EN 61000 6 2 ed 3 2005 EN 61000 6...

Page 3: ...e operated easily and measure correct values of temperature i e in the height of about 150 cm with no direct sunlight or other heat cool source AHU outlets refridgerator electrical appliances The device consists of two parts bottom with screw terminal block and cover containing PCB display and the knob The bottom part is fixed by 2 or 4 screws to any flat surface or a flush mounting box Ø 50 mm At...

Page 4: ... only at the sides of the display part not at the top nor bottom Display A large 60 x 60 mm display clearly shows actual room temperature and controller status with 7 segment digits and standard Day Night Off and Time scheduler symbols Active output is indicated by a heating symbol In the upper part there are week days used for time scheduler setup Other symbols are not used LCD symbol set ...

Page 5: ... air conditioning systems It must not be used for protection of persons against health risks or death as a safety element or in applications where its failure could lead to physical or property damage or environmental damage All risks related to device operation must be considered together with design installation and operation of the entire control system which the device is part of ...

Page 6: ...6 08 2018 Subject to technical changes domat UC905 Changes in versions 10 2017 The first datasheet version 08 2018 Minor changes ...