Domaplasma IQS Series User & Installation Instructions Manual Download Page 9

 

 

High voltage is used within the device for the generation of plasma. It is therefore 
essential  that  the  power  plug  is  removed  from  the  power  connection  during 
installation or maintenance of the Domaplasma

®

 filter. 

 

 

In the event of any damage, the device should not be used. 

 

 

The device is intended for use in domestic kitchens. 

 

 

Use only with the voltage as specified on the type plate. 

 

 

It is strictly forbidden to modify or convert the product. 
 
 
 

2.2

 

Regulations for maintenance and cleaning

 

 

 

During all maintenance and cleaning activities, the power plug must be removed 

from the power connection or the (main) power switch of the specific connection 
or the house must be turned off. 
 

 

Maintenance and cleaning the interior of the Domaplasma

®

 filter must be carried 

out by the producer, or any warranty or responsibility is invalidated. 

 

 

2.3

 Tips for achieving maximum efficiency deodorization 

 

 
Smoke emission 

 

 

‘Smoke’ is generated by burned oil and/or fat particles, caused by (too) hot frying 

oil/fat  or  singed  meat.  If  the  fat  reaches  too  high  temperatures  or  the  baking 
process takes too long, blue smoke or soot formation occurs. These particles are 
so small that they get through all filtration systems. The formation of blue smoke 
depends  on  the  baking  process,  cooking  with  gas  is  hotter  and  partly  for  this 

reason,  this  phenomenon  manifests  itself  more  quickly  than  for  example  with 
induction cooking. 
  

 

Which type of recirculation cooker hood you choose, low-priced or expensive, the 
phenomenon of smoke formation will always occur. Air circulation means nothing 

other than air aspiration and blowing the air out in the same room.  

 

 

The solution should be found in the baking process. By not allowing products to 
burn and in addition mechanically ventilate to gradually discharge smoke particles. 

 

 

Always  start  the  cooker  hood  in  the  middle  setting  in  order  to  activate  the 

catalyser, subsequently select the lower or higher setting you wish to use. 

 

 

Summary of Contents for IQS Series

Page 1: ...IBDp IQS 03 2018 GB USER INSTALLATION INSTRUCTIONS DOMAPLASMA IQS MODELS IQS650 IQS850 ...

Page 2: ...or installation and use 8 2 2 Regulations for maintenance and cleaning 9 2 3 Tips for achieving maximum efficiency deodorization 9 10 3 Installation 11 3 1 Installation instructions 12 3 2 Electrical connection 12 3 3 Metal grease filter 13 3 4 Installation of the Hyabsorb filters 13 15 4 Contact information producer 16 5 Enclosures 5 1 VDE Certificate IQS650 IQS850 17 18 5 2 CB Certificate 19 5 3...

Page 3: ...asma received as the first company in this field the VDE certificate Nr 40046744 see the first 2 pages as well as the CB certificate Nr DE1 58593 You will find these pages enclosed in this document Fact the unique Domaplasma low temperature plasma technology is extremely effective powerful widely scalable multipurpose and very energy efficient and therefore your certified emission free and safe ul...

Page 4: ...order to create a low temperature plasma whereas our nature applies sunlight i e photons A variety of solutions all powered by Domaplasma is available in several standard models and capacities which all are because of a unique internal pressure sensor fully independent regarding the electronic controls of whatever brand of cooker hood to be used with When suitable we can adapt shapes and capacitie...

Page 5: ...uest 1 Your address 2 Your telephone and fax number if applicable 3 When can thecustomer service visit you 4 Exact device designation name see type plate and or proof of purchase Model name Item number Product code Date of purchase 5 Detailed description of problem or desired service Please keep your proof of purchase to hand This way you can help us save time and costs and ensure we can help you ...

Page 6: ...Please read these instructions carefully and keep them in order to consult this information later if required This user guide may if applicable be passed to the new owner Only with proper installation according to the instructions safety is ensured during use The installer is responsible for proper application on location Please NOTE When the plasma filter is meant to be attached to a downdraft sy...

Page 7: ...o ensure your own safety Attention Instructions to prevent damage to the device INSTALLATION POSITION The Domaplasma IQS is equipped with three air outlets these are the black areas on the sides of the device The Domaplasma unit must always be installed a in a horizontal position lying with the backside on the surface b in a horizontal position with the backside attached to the ceiling or c in a v...

Page 8: ...aplasma filter should only be used on cooker hoods in combination with high quality metal grease filters on the hood which are equipped with at least 8 layers wire mesh If this is not the case the supplied Hyabsorb fine filter should be cut to the size of the grease filters of the cooker hood and applied to the filters using the supplied stainless steel rods The metal grease filters of the cooker ...

Page 9: ...ency deodorization Smoke emission Smoke is generated by burned oil and or fat particles caused by too hot frying oil fat or singed meat If the fat reaches too high temperatures or the baking process takes too long blue smoke or soot formation occurs These particles are so small that they get through all filtration systems The formation of blue smoke depends on the baking process cooking with gas i...

Page 10: ...ack fine filters are not cleaned regularly the Domaplasma air purification technology will get filthy faster and lose its effectiveness in the long run Install the supplied Hyabsorb filter on the metal grease filter of the cooker hood By cleaning this filter regularly internal greasing of the Domaplasma filter is prevented If you bake more than you cook during a certain period thus with relatively...

Page 11: ...r outlets are located on the three black sides of the Domaplasma filter Ensure that those three sides are not placed against the wall or ceiling or cabinet when installing the Domaplasma filter The black areas serve as air outlets The backside which contains no black air outlet is meant to be placed against the wall or ceiling The Domaplasma unit must always be installed a in a horizontal position...

Page 12: ...raft The Domaplasma filter is now properly installed on or to the cooker hood 5 Take the supplied power cable and connect it to the C14 connection of the Domaplasma filter Connect both the plug of the Domaplasma filter and the plug of the cooker hood to the power connection s 3 2 Electrical connection Check before plugging into the electrical connection whether the data on the type plate and the l...

Page 13: ...od which are equipped with at least 8 layers wire mesh If this is not the case the supplied Hyabsorb fine filter must be applied to the metal grease filters of the cooker hood The properly installed Hyabsorb filter can still attached to the metal grease filters be cleaned in the dishwasher at 55 to 60 C 3 4 Installation of Hyabsorb filters 1 Take the metal grease filter s from the cooker hood befo...

Page 14: ...starting on the inside of the metal grease filter framework and ending on the outside and cut the rods on the correct length Fig 6 Fig 7 5 When the mounting rods are cut to the correct length take a thin screwdriver and make small openings on the inside of the aluminium framework which can later be used to insert the rods These will keep the Hyabsorb fine filter in place Ensure that the openings a...

Page 15: ...mounting rod beginning with the vertical rods in the slots Fig 12 Fig 13 Fig 14 The Hyabsorb fine filter is now installed on the metal grease filter and ready for use Repeat the above procedure for the remaining metal grease filters if appropriate and place them back in the cooker hood The Domaplasma filter is now ready for use ...

Page 16: ...and place back placing back can be done while the filter is still slightly moist 4 Contact details producing company Producer Domaplasma BV Address Felland 5c NL 9753 TA HAREN P O box 143 NL 9750 AC HAREN Telephone 31 0 50 205 30 64 Fax 31 0 50 534 98 25 Email info domaplasma com Copyright No part of this publication may be copied or reproduced without permission of the publisher In case this guid...

Page 17: ...17 5 1 VDE Certificate IQS ...

Page 18: ...18 ...

Page 19: ...19 5 2 CB Certificate ...

Page 20: ...20 5 3 Your notes ...

Reviews: