CT120G Mini Series Inverter 3 Parameter Table
- 39 -
Function
code
Name
Detailed instruction of
parameters
Default
value
Attribu
-tion
F08.12
Output phase loss
protection selection
0: disabled
1: enabled
11
○
F08.13
Automatic reset
times
0
~
20
1
○
F08.14
Automatic reset
interval
0.1s
~
100.0s
0
○
F08.15
Motor overload
pre-alarm
coefficient
50%
~
100%
1.0
○
F08.16 First fault type
0: no fault
1:reserved
2:reserved
3:reserved
4: ACC overcurrent (E.oC1)
5: DEC overcurrent (E.oC2)
6: constant speed overcurrent
(E.oC3)
7: ACC overvoltage (E.oU1)
8: DEC overvoltage (E.oU2)
9: constant speed overvoltage
(E.oU3)
10: bus undervoltage fault
(E.Lv)
11: motor overload (E.oL1)
12: inverter overload (E.oL2)
13: input side phase loss
(E.ILF)
14: output side phase loss
(E.oLF)
15: rectifier radiator
overheating (E.oH1)
16: inverter radiator
overheating (E.oH2)
0
●
F08.17 Second fault type
0
●
F08.18
Third fault type
( latest fault)
0
●