1. Press
2. Enter the “Master Code” (default is )
3. Press the button
4. Enter for change code
5. Enter for “Master Code”
6. Enter the new “Master Code” (Must be 4 digits)
7. Press the button. The multi-color status LED flashes Green 3 times meaning
the code is accepted. If the multi-color status LED flashes 3 times Red, the
steps need to be repeated.
S1
S1 Frequency Selection
GND
GND OP VIN
CON1
ON
S2
10
1 2 3 4
300Mhz
318Mhz
DIP
10
DIP
1
2
3
4
4 Sec
2 Sec
1 Sec
ON
S2 Function Config
3 State/9 PORT 2 State/10 PORT
OFF
STEP 1:
Set Jumper S1
S1
S1
318 MHz
300 MHz
Figure 1
jumper
in place
Determine the operating frequency you
will use on your keypad installation. This
keypad can operate at either 300 MHz
or 318 MHz. At 300 MHz the keypad is
compatible with all 300 MHz receivers
with 10 dip switches. At 318 MHz the
keypad is compatible all 318 MHz
receivers with 9 dip switches.
(see Figure 1)
STEP 2:
Set Jumper 4 on S2
• 300 MHz (10 dip switches)
- Jumper set to OFF (in the DOWN position)
• 318 MHz
(9 trinary dip switches)
- Jumper set to ON (in the UP position)
STEP 3:
Set the DIP switches to match the Receiver
Set the DIP switches of the keypad to “
+
” for ON or CLOSE, and “
-
” for OFF or
OPEN. Note: Do not use the center position.
STEP 4:
Programming the Master Code
1
1
*
*
*
4
3
2
0 0
ON
S2
1 2 3 4
ON
S2
1 2 3 4
318 MHz
(9 dip switch)
10
DIP
300 MHz
(10 dip switch)
not used