background image

IMPORTANT

When use AC power supply, it must be connected with the Red wire(AC1) 
and the Pink wire (AC2) of the reader. It is forbidden to connect the AC 
power to Black wire (GND), or the reader will be damaged. Install a 
1N4004 or equivalent diode is needed when use a common power 
supply, or the reader might be damaged. (1N4004 is included in the 
packing).

SET CARD READING TYPE

NOTE:

•  If no Master Cards added, must press the Exit Button for at 

least 10 seconds before release
•  Reset to Factory default, the user's information is still retained.

TO RESET TO FACTORY DEFAULT: Power off, press the Exit 
Button, hold it and power on, there will be two beeps, and the 
LED light turns into orange, release the exit button, then read any 
two 125KHz EM card or HID card, the LED will turn into red, 
means reset to Factory default successfully. Of the two cards 
reading, the 1st one is Master Add Card, the 2nd one is the 
Master Delete Card.

Master Code

*

*

Programming Step         Keystroke Combination

Enter Programming Mode 

Read EM & HID® card

OR
Read EM card only

OR
Read HID® card only

#

9 3 #

Exit

(factory default)

9 4 #

9 5 #

MASTER CARD USAGE

Using Master Card to add and delete card users

Add a Card User

Delete a Card User

1. (Read Master Add Card)
2. (Read User Card)
Repeat Step 2 for additional user cards
3. (Read Master Add Card)

1. (Read Master Delete Card)
2. (Read User Card)
Repeat Step 2 for additional user cards
3. (Read Master Delete Card)

Summary of Contents for DOLCSAW1000H

Page 1: ...1 Quick Start Guide 2 Installation and Wiring 3 Connection Diagram 4 Programming Guide DOLCSAW1000H Reader USER MANUAL VIDEO INSTRUCTIONAL...

Page 2: ...doors Built in light dependent resistor LDR for anti tamper Low temperature resistance 40 F SPECIFICATIONS User Capacity Common User 1000 998 Operating Voltage Idle Current 12 24VAC DC 35mA Proximity...

Page 3: ...THE BOX Master Code Default Master Code is 123456 Function Description Operation Enter Programming Mode Change the Master Code Add Card User Delete User New Master Code Repeat New Master Code 0 Exit f...

Page 4: ...ll for the screws and one hole for the cable Knock the supplied rubber bungs to the screw holes A C Fix the back cover firmly on the wall with 4 flat head screws Thread the cable through the cable hol...

Page 5: ...Relay NC Normally Closed Relay Output Install diode provided Yellow OPEN Output Install diode provided Advanced Input and Output Features Grey Alarm Output Negative contact for Alarm Brown Contact In...

Page 6: ...COM NO AC1 DC AC2 D IN _ OPEN ALARM D0 D1 GND DC Power DC Alarm Exit Button Door Contact AC Power Supply In4004 In4004 K K Magnetic Lock or Fail Safe Lock Fail secure lock DC POWER SUPPLY AC POWER SUP...

Page 7: ...d Any 125KHz industry standard 26 bit EM and HID Proximity card or Tag Master Code Cards can be added continuously READ CARD READ CARD 1 Programming Step Keystroke Combination Enter Programming Mode A...

Page 8: ...ard Input 8 10 digit card number Input 8 10 digit card number User ID 1 Exit Master Code Programming Step Keystroke Combination Enter Programming Mode Delete Card User Common Delete Card by Card OR De...

Page 9: ...r Programming Mode Strike Out OFF OR Strike Out ON OR Strike Out ON alarm Set alarm time SET STRIKE OUT ALARM 6 0 Exit factory default 6 1 Access will be denied for 10 minutes 6 2 5 The strike our ala...

Page 10: ...d means reset to Factory default successfully Of the two cards reading the 1st one is Master Add Card the 2nd one is the Master Delete Card Master Code Programming Step Keystroke Combination Enter Pro...

Page 11: ...DS EXPRESS OR IMPLIED INCLUDING WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICU LAR PURPOSE BUYER MAKES NO RELIANCE ON ANY REPRESENTATION OF TRANSMITTER SOLUTIONS EXPRESS OR IMPLIED W...

Page 12: ...3850 West 2480 South Suite B Salt Lake City UT 84120 866 975 0101 866 975 0404 fax www transmittersolutions com...

Reviews: