background image

BC633

Series 

|  

Dolphin Blue  

|  

11

If desired, use the remote control to adjust the soap dispenser settings. Hold the

remote control straight in front of the sensor in a distance of about 10-15cm.

Attention: 

Holding the soap dispenser remote control out of the recommended

range (too close or too far) may interfere with the remote’s activation. 

Choose the function you want to adjust by pressing on the function button as

follows:

1 SOAP QUANTITY

The 1-4 drop keys allow the user to choose the 

desired soap quantity. 

1: 

0.2 to 0.4  

2:

0.7 to 0.9  

3: 

1.2 to 1.6  

4:

2.1 to 2.3

Indication: 

continues blink of the red light in the

sensor eye.

* The exact soap dosage depends on the soap viscosity.

2 ADJ

This function allows coming back to soap quantity factory settings. Press the ADJ

button. Indication: 2 blinks of the red light in the sensor eye.

3 TEMPORARY OFF FUNCTION

This function is ideal to perform any kind of activity in front of the sensor without

operating the system (for example, cleaning). The soap dispenser will remain shut

for 1 minute when this button is pressed once. To cancel this function and to return

to normal operation press the On/Off button again or wait 1 minute.

Indication: OFF – 2 fast blinks, ON – 4 fast blinks

4 REFILL THE SOAP TANK

Once the soap tank has been refiled, press the FILL button. The pump would work

for one minute in order for the soap to start coming out of the soap dispenser

spout. To stop this activity press the FILL button again.

SETTINGS ADJUSTMENTS
WITH REMOTE CONTROL

Summary of Contents for BC633

Page 1: ...October 2020 BC633 DOLPHIN ELECTRONIC SOAP DISPENSER I N S TA L L AT I O N A N D M A I N T E N A N C E G U I D E ...

Page 2: ...es 3 Technical Data 5 Pre Installation Info 6 Pack Contents 7 9 Installation 10 FillingThe SoapTank 11 Settings Adjustment 12 Battery Replacement 13 Spare Parts List 14 Maintenance 15 Limited Warranty 17 Trouble Shooting INDEX ...

Page 3: ...y 1 Litre 33 8 oz Battery models IP 67 Battery Box for 6xD Alkaline batteries Mains models 9V transformer or 12V transformer Soap viscosity 100 3800 cPs Standard discharge 1 4cc Adjustable Sensor range 30 100 mm 10 mm Adjustable by remote control BC633 ...

Page 4: ...4 Dolphin Blue BC633 Series BC633F ...

Page 5: ...free soap dispenser until you obtain the missing parts Warnings Do not install the system facing a mirror or any other electronic system operated by an infra red sensor To prevent reflection problems it is recommended to keep a minimum distance of 1 5 metres between the soap dispenser and any other objects IMPORTANT Keep in mind that the location of the user hands while using the tap nearby should...

Page 6: ...iarise yourself with the part names and confirm that the parts are included PACK CONTENTS 1 x body and fixing accessories 1 x IP 67 battery box for 6xd alkaline batteries transformer 1 x soap tank with bottle support and pump assembly ...

Page 7: ... base of the soap dispenser body Step 2 installing the soap dispenser 1 Place the soap dispenser body along with the bottom ring into the hole in the deck or lavatory 2 Under the deck slide the gasket disk and nut over the soap dispenser body nipple and secure it firmly BC633 Series Dolphin Blue 7 ...

Page 8: ...d location 4 Screw in the nut Marked A at the topof the soap dispenser pump assembly to the nipple Marked B that is located at the end of the tube of the soap dispenser body Step 3 connecting the power source 1 Remove the protective sticker covering the sensor Keep away from the sensor range ...

Page 9: ...nd connect the battery connector 2b For transformer versions plug the transformer into the electricity socket and connect the transformer connector 3 Wait about 10 seconds before you put your hands within the sensor range IMPORTANT the 4 contacts connector should be connected properly so that the white o ring is not visible and a clicking sound is heard PAY ATTENTION If the 4 contacts connectors w...

Page 10: ...ap tank back to the pump assembly Make sure the tank is firmly secured into place 5 Press the refill button located at the back of the pump assembly until soap starts coming out of the soap dispenser spout This operation can also be done using the soap dispenser remote control Refill function 6 NOTE Once the soap in the soap tank has reached the bottom line the soap tank should be refilled To refi...

Page 11: ...depends on the soap viscosity 2 ADJ This function allows coming back to soap quantity factory settings Press the ADJ button Indication 2 blinks of the red light in the sensor eye 3 TEMPORARY OFF FUNCTION This function is ideal to perform any kind of activity in front of the sensor without operating the system for example cleaning The soap dispenser will remain shut for 1 minute when this button is...

Page 12: ...o weeks To replace the battery in battery models 1 Carefully open the battery box use 2 5 mm Allen key 2 Remove the old batteries 3 Replace the used batteries with new D batteries NOTE Do not mix used batteries with new ones 4 Close the box BATTERY REPLACEMENT Important Spent batteries should not be disposed of with normal household waste Contact your local authority for information on waste dispo...

Page 13: ... LIST Sensor for BC633 BC07220250 Soap bottle 1L BC07100020 12VTransformer BC06522086 Soap dispenser pump assembly BC07222028 Remote control BC07100008 IP 67 Battery Box for 6xD Alkaline batteries BC06530041 Bottle support 1 litre BC07120175 ...

Page 14: ... abrasives or the like Use of any prohibited cleaning or maintenance products or substances could damage the surface of the soap dispenser For surface cleaning use ONLY soap and water then wipe dry with a clean cloth or towel When cleaning bathroom tiles the soap dispenser should be protected from any splattering of harsh cleansers MAINTENANCE ...

Page 15: ...e In no event shall the liability of Dolphin exceed the purchase price of the product If you believe that you have a warranty claim contact your Dolphin Solutions Distributor Dealer or Plumbing Contractor Please be sure to provide all pertinent information regarding your claim including a complete description of the problem the product model number the date the product was purchased from whom the ...

Page 16: ...tween the motor and the electronic unit are not connected properly Eliminate cause of reflection Sensor is picking up reflections from the washbasin or another object Red light in the sensor does not flash once when user s hands are within the sensor s range Connect the electronic unit connectors to the power source connector Connectors between the electronic unit and power source are disconnected...

Page 17: ...BC633 Series Dolphin Blue 17 ...

Page 18: ...18 Dolphin Blue BC633 Series ...

Page 19: ...BC633 Series Dolphin Blue 19 ...

Page 20: ...Dolphin Solutions Ltd Southpoint Compass Park Bodiam Robertsbridge TN32 5BS Tel 44 0 1424 20 22 24 Fax 44 0 1424 205 200 info dolphinsolutions co uk www dolphinsolutions co uk ...

Reviews: