Parameterization using the display
To enter the device’s parameterization mode the following key combina-
tion is provided:
Press and keep pressed the right key at first. Then, press the left key
(see below). A display test follows and has to be acknowledged using the
OK key (right key) when it was successful. Then, it is possible to change
the parameterization. Before the device adopts changed parameters, they
must be confirmed once more for safety reasons.
Parameterization
M10375
Automatic operation
80 - 100 m/min
Standstill
< 10 m/min
Device:
UH 5947
Device No:
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Configurated by:
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Date:
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1. Parameterization
1.1 Monitored motion
1)
Translational
Rotational
1.2 Encoder type
1)
Lin. encoder
Rot. encoder
1.3 Encoder selection
RJ45:E E2
RJ45:Encoder
E1 + E2
1.4 Lead / transm.
Transmission
: 1
Lead
mm
1.5 Encoder settings
Signal form
sin/cos or TTL
x
HTL
Resolution
xxxxxx e.g. xxx,xxx
Imp/U e.g. mm
1.6 Sensor settings
Sensor type
pnp
npn
Resolution E1
Imp/U e.g. mm
Resolution E2
Imp/U e.g. mm
1.7 Speed limits
Automatic max
U/min e.g. m/min
Automatic min
U/min e.g. m/min
Set-up max
U/min e.g. m/min
Set-up min
U/min e.g. m/min
Standstill
U/min e.g. m/min
1.8 Times
Start override
s
Release delay
s
Switch-off monit.
s
1.9 Start type
Manual start
Automatic start
1.10 Prot. door monit.
Simultaneity on
Simultaneity off
Formular for documentation of the setting parameters