Configurable Safety System SAFEMASTER PRO
87
0265525 / 16.05.19 en / 101A
ERROR CODES FROM SAFEMASTER PRO DESIGNER
In case of malfunction the SAFEMASTER PRO system transmits to the SAFEMASTER PRO Designer a code correspon-
ding to the error detected by the UG6911.10 unit.
To read the code, proceed as follows:
- Connect the UG6911.10 (indicating Fail) to the PC using the USB-cable
- Launch the SAFEMASTER PRO Designer, a window appears with the error code occurred.
The following table lists all possible errors detected and their solution:
CODE
FAIL
RESOLUTION
19D
The two UG6911microcontrollers do not see the same
hardware / software configuration
Check correct insertion of UG 6911 and expansions
modules in In-Rail Bus
66D
2 or more same expansion modules
with the same node number
Check the connections of Pins 2 and 3
of the expansions modules
68D
Exceeded max expansion modules number
Disconnect the modules in excess (max. 14)
70D
One or more modules have detected a change
in the node number
Check the connections of Pins 2 and 3
of the expansions modules
73D
A slave module has detected an external error
Check the error code on module for more information
96D ÷ 101D
Errors related to memory card OA6911
Replace memory card OA 6911
CODE
UG 6914 FAIL
RESOLUTION
137D
EDM error on the couple Relay 1 and 2 used in Category 4
Check the connection of the external feedback contactors
147D
EDM error on the couple Relay 2 and 3 used in Category 4
157D
EDM error on the couple Relay 3 and 4 used in Category 4
CODE
UG 6917 FAIL
RESOLUTION
133D (Proxi1)
140D (Proxi2)
Over-frequency detected on Proximity input
The input frequency must be
≤
5 kHz
136D (Encoder1)
143D (Encoder2)
Input signals not standard
(duty cycle, phase displacement)
• DUTY CYCLE must be 50 %
±
33 % of the PERIOD
(HTL, TTL)
• The phase displacement must be 90°
±
33 %
(HTL, TTL) (not applicable to sin / cos)
138D (Encoder1)
145D (Encoder2)
Over-frequency detected on Encoder input
The input frequency must be
< 500 kHz (TTL, sin / cos); < 300 kHz (HTL).
CODE
FAIL
RESOLUTION
194D 197D
198D 199D
201D 202D
203D 205D
Errors solid state output OSSD1
Check the OSSD1 connection relative
to the module in error
208D 211D
212D 213D
215D 216D
217D 219D
Errors solid state output OSSD2
Check the OSSD2 connection relative
to the module in error
222D 225D
226D 227D
229D 230D
231D 233D
Errors solid state output OSSD3
Check the OSSD3 connection relative
to the module in error
236D 239D
240D 241D
243D 244D
245D 247D
Errors solid state output OSSD4
Check the OSSD4 connection relative
to the module in error
All other codes are related to errors or an internal malfunction.
Please replace the module that gave the error or return to DOLD for repair and / or debugging.