Configurable Safety System SAFEMASTER PRO
41
0265525 / 16.05.19 en / 101A
INPUT / OUTPUT MODULE UG 6916.10
INPUT / OUTPUT MODULE UG 6916.12/080
SFF:
(IEC 61508: 2
nd
edition)
99.8 %
PFH
d
:
5.68E-9
MTTF
d
:
EN ISO 13849-1: 2008
458.21
DC
avg
:
99.0 %
Nominal voltage:
24 V DC
±
20 % / PELV, PREDective Class III; UL: Supply from class 2 (LVLE)
Nominal consumption:
Max. 3 W
Digital safety inputs (No. / description):
8 / „Type 2“ acc. to EN 61131-2 IN: 7 to 10 mA at DC 24V
Inputs for Node selection NODE_SEL0/1
(No. / description):
2 / „Type 2“ acc. to EN 61131-2 IN: 7 to 10 mA at DC 24V
Test output (No. / description):
4 / to check for short-circuits - overloads
Digital status outputs (No. / description):
2 / programmable - PNP active high; max. 100 mA at 24 V DC
OSSD (No. / description):
2 pairs / solid state safety outputs PNP active high;
max. 400 mA at 24 V DC
Input FBK/RESTART
(No. / description):
2 / EDM control / possible Automatic or Manual operation with RESTART button
„Type 2“ acc. to EN 61131-2, IN: 7 to 10 mA at DC 24 V
Connection to control unit:
Proprietary 5-pole DOLD IN-RAIL-BUS
Weight:
190 g
Approvals:
SFF:
(IEC 61508: 2
nd
edition)
99,7%
PFH
d
:
1.32E-8
MTTF
d
:
EN ISO 13849-1: 2008
166,47
DC
avg
:
99,0%
Nominal voltage:
24 V DC
±
20 %
Nominal consumption:
Max. 3 W
Digital safety inputs
(No. / description):
8 / „Type 2“ acc. to EN 61131-2 IN: 7 to 10 mA at DC 24 V
Inputs for Node selection NODE_SEL0/1 (No. /
description):
2 / „Type 2“ acc. to EN 61131-2 IN: 7 to 10 mA at DC 24 V
OUTPUT Test (No. / description):
4 / to check for short-circuits - overloads
Digital status outputs (No. / description):
4 / rogrammable - PNP active high, max. 100 mA at 24 V DC
OSSD (No. / description):
4 single (or 2 dual channel), Cat.4: PNP active high –
max. 400 mA at 24 V DC; Schnittstelle Typ C Klasse 3 (ZVEI CB24I)
Connection to control unit:
Proprietary 5-pole DOLD IN-RAIL-BUS