19
BH 5928, BI 5928 / 13.12.18 en / 046A
BH 5928._ _/_ _ _ /61:
with UL approval
BH 5928._ _/001:
with fix time delay
fixed times: 1 s, 3 s, 5 s, 10 s, 300s
other times on request
BH 5928._ _/900:
with adjustable time delay
suitable for light curtains and
reed contacts switches
BI 5928.47/100:
with adjustable time delay
tolerates voltage drop
up to 6 V in e-stop circuit
Ordering example for variants:
B_ 5928. _ _ / _ _ _ DC 24 V
50/60 Hz 1 ... 10 s
0.1 ... 1
s
0.3 ... 3
s
0.5 ... 5
s
1
... 10 s
30 ... 300 s
for fixed time end of scale value,
other ranges on request
Nominal frequency
Nominal voltage
Variant, if required
Contacts
.47 = 3 NO contacts,
1 NC contact instantaneous and
1 NO contact release delayed
.91 = 2 NO contacts instantaneous and
2 NO contacts release delayed
(only at BH 5928)
.92 = 2 NO contacts,
1 NC contact instantaneous and
3 NO contacts release delayed
.93 = 3 NO contacts instantaneous and
3 NO contacts release delayed
H:
width 45 mm
I:
width 67.5 mm
BH 5928.92/61 DC 24 V 0.5 ... 5 s
Article number:
0060264
• Output:
2 NO contacts, 1 NC contact instantaneous
and 3 NO contacts release delayed
• Nominal voltage U
N
:
DC 24 V
• Time delay tv:
0.5 ... 5 s
• Width:
45 mm
Quadratic total current limit curve
Arc limit curve (instantaneous contact)
Arc limit curve (delayed contact)
Standard Type
Variant
Characteristics
0
0,1
0,3 0,5
1
3
5
10
switching current A
50
100
150
250
200
sw
itc
hi
ng
vo
lta
ge
VD
C
M
58
34
_c
safe breaking, no continuous arcing,
max. 1 switching cycle / s
0
0,1
0,3 0,5
1
3
5
10
switching current A
50
100
150
250
200
sw
itc
hi
ng
vo
lta
ge
VD
C
M
28
71
_c
safe breaking, no continuous arcing,
max. 1 switching cycle / s