14
STOP
8. DESCALING AT LEAST EVERY 3 – 4 MONTHS
9
Empty and clean container. Rinse and clean
water tank. Use a clean food-safe brush and
washing-up liquid as needed. Afterwards
refill with fresh drinking water and insert it into
machine.
12
At the end of the rinsing cycle, power button
lights up red. Wait until power button light
turns green. Remove container. Switch off
machine.
13
14
Pull out capsule holder. Remove rinsing
tool. Reinsert capsule holder. Empty and
clean container. Rinse and clean water tank.
Afterwards refill with fresh drinking water and
insert it into machine.
Clean machine with a soft damp cloth. Dry it
afterwards with a soft dry cloth. Place drip grid
on drip tray. Then insert drip tray at desired
position.
STOP
10
Push selection lever to the “HOT” position. Wait
until the lever moves to the “STOP” position.
Extraction stops.
Push selection lever to the “COLD” position.
Wait until the lever moves to the “STOP”
position. Extraction stops.
11
STOP
7
8
Push selection lever to the “COLD” position.
Machine descales continuously. Lever comes
back to the middle position.
For a better effect of the descaler, the machine
enters a waiting time of 2 minutes. The power
button blinks green during the waiting time.