Opticooler |
Temperature. That Arrives.
Author: M. Thran
Operation Manual Opticooler-TS V1 30_ 2019_05_09.docx09
Page 40 of
44
Version: 1.30
Issued: 09. May 2019
5.3. Alert: Temperature Deviation
Has the container been properly
pre-conditioned?
Ensure container temperature has
been given time to reach the
requested temperature range.
Is the container stored at a
temperature above +50°C or below
-30°C?
Move container to cooler area
below 50°C or warmer area above -
30°C.
Has the container recently been
exposed to sun/cold winds and/or
high/low temperatures?
Monitor if the internal temperature
returns to the set temperature
range.
Have the doors been opened
recently?
Replace the container.
Make sure
that the cargo is put in a
temperature controlled area.
Have the doors been properly
closed?
Close the doors and wait until
temperature stabilizes
Replace the container.
Make sure
that the cargo is put in a
temperature controlled area.
no
no
no
no
no
yes
yes
yes
yes
yes
Is the battery capacity
above 5%?
Charge the container, see 3.2.3.
charging procedure
no
yes