background image

Instructions manual

 / GX Screwdrivers

 

 

9

10. Operation 

10.1 Speed change in standard model ( GX___ ) 

 

 

1) Keep pressing the Lock button for 2 second to visit 

 

to PROGRAM mode. Then two LED lights will display 

 

the set speed. 

 
 

2) Select "Reverse" of F/R switch for increasing speed 

 

or select "Forward" of F/R switch for increasing speed. 

 
 

3) Press "Speed" button and select the target speed. 
The set speed can be recognized by the colors of two 
LED as below. 
 
4) Keep pressing the Lock button for 2 second to go 
back to operating(work) mode. 

 
 

 Speed display by two LED color (Standard model) 

LED 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Model 

Button 

1th 

2nd 

3rd 4th 5th 6th 7th 8th 9th 

GX150 

RPM  800 900 1000 1100 1200 1300 1400 1500 1700 

GX220 

RPM 600 

650 700 750 800 900 1000 1100 1250 

GX450 

RPM 300 

340 380 415 450 490 530 565 600 

 
 

10.2 Soft start & Double hit ( GX___+ ) 

 

Model : GX150+, GX220+, GX450+, , ,  
The Plus option drivers have the single speed of the maximum in the speed range. 
 

 Double Hit 

When "Double Hit" is chosen by the Double Hit button, LED A will light Orange color. 
During the motor run, LED A will display Green light. 
 
 
 
 
 
 
 
 
 
 
 
 

 Soft Start 

The rotation speed reaches to the target speed 
gradually after the soft start time as below. 

 Green : 0.2 second 

 Red : 0.4 second 

 Orange : 0.6 second 

 

Summary of Contents for GX150

Page 1: ...Instructions manual GX Screwdrivers 1 GX Screwdrivers 40 Volts INSTRUCTIONS MANUAL INSTRUCTIONS MANUAL...

Page 2: ...NG G This informations has to be kept in a location known all users Each operator has to read carrefully this manual before installing using and mending the product Be sure that the operator has under...

Page 3: ...Never lubricate aerosol oil on to the electrical part 5 3 ELECTRIC SPECIFICATION 6 4 MECHANICAL SPECIFICATION OF XS 40D 6 5 INPUT POWER SELECT 6 6 SCREWDRIVER SPECIFICATION 7 7 TORQUE CURVE AT NO LOA...

Page 4: ...are rated for outdoor use and reduce the risk of electric shock 1 3 Personal Safety Stay alert watch what you are doing and use common sense when operating a power tool Do not use tool while tired or...

Page 5: ...ome hazardous when used on another tool 1 5 SERVICE Tool service must be performed only by qualified personnel Service or maintenance performed by unqualified personnel could result in a risk of injur...

Page 6: ...40V Output 30 40VDC selectable Rated power 2 5A 95W Maximum output current 8 A Intermittent operation 10s On 30s Off Safety system CE certified Class I Class III 4 Mechanical specification of XS 40D S...

Page 7: ...3 15 800 1700 GX 220 ESD 6 22 600 1250 GX 450 ESD LEVER 7 45 300 650 GX 150P ESD 3 15 800 1700 GX 220P ESD 6 22 600 1250 Speed control GX 450P ESD PUSH 7 45 300 650 GXT 150P ESD 3 15 800 1700 GXT 220P...

Page 8: ...trol Auto reverse GXT___ 9 Alarm display by LED n o Alarm Description Reset 1 Over Voltage over 48V Green light blinks for 0 5s Auto reset under 48V 2 Overload 4A 0 5s Red light blinks for 0 5s Auto r...

Page 9: ...ode Speed display by two LED color Standard model LED Model Button 1th 2nd 3rd 4th 5th 6th 7th 8th 9th GX150 RPM 800 900 1000 1100 1200 1300 1400 1500 1700 GX220 RPM 600 650 700 750 800 900 1000 1100...

Page 10: ...torque even it does not reach the target angle Stop and hold for set time Rotate reverse until releasing the lever or stop at the target torque Time setting 0 5 sec 30 steps 0 5 sec 12 steps x Screwdr...

Page 11: ...g set angle or F position for decreasing set angle Keep the first Run button pressed over 2 sec for Lock operating mode Time setting for stop HOLD Keep the stop time button pressed over 2 sec Then cli...

Page 12: ...eed or F position for decreasing speed Keep the first Run button pressed over 2 sec for Lock operating mode Angle setting for Reverse RUN Keep the both first Run stop time buttons pressed over 2 sec f...

Page 13: ...Normal screwdriver It stops at the set torque Angle control ON 1 off off It stops at set angle 1 Tapper or Insert fastening ON 1 ON 2 ON 3 or off It stops at set angle 1 and waits for set time 2 and m...

Page 14: ...Instructions manual GX Screwdrivers 14...

Page 15: ...Instructions manual GX Screwdrivers 15...

Page 16: ...Instructions manual GX Screwdrivers 16 06 17 60178 05 10...

Reviews: