3931195/03/10/F
7
Doepke
12. Guarantee
All professionally installed, unaltered devices are covered by warranty during the statu-
tory guarantee period from the day of purchase by the end user. The guarantee is not
applicable to damage incurred during transport or caused by short-circuit or overloading.
In the event of defects in workmanship or material, which are discovered within the gua-
rantee period, the company will provide a replacement free of charge. The guarantee will
be rendered null and void if the device is opened or tampered with.
Inputs
Type semiconductor inputs
Contact load
1 mA
Permissible switch bounce time
10 ms
Permissible inh. contact resistance
1 kOhm
Permissible line length
3 m (in industrial environment: 1 m)
Outputs
Type Switching relays
Rated voltage
230 VAC
Rated current
2 A
Power factor
cos
ϕ
= 0.6 - 1
Operating voltage
Rated operating voltage
210 VAC
230 VAC
250 VAC
Current input
8 mA
10 mA
12 mA
Terminals
Control terminals
Type 2- and 3-pole plug terminals (fitted)
Contact area
0.6 mm
∅
0.8 mm
∅
Mains terminals
Type 4 leads LiY with wire end ferrules
Contact area
0.75 mm²
Housing
Type Strap-type enclosure
Dimensions 42 x 42 x 34 (W x H x D in mm)
Material Polyamide PA6
General technical data
Operating temperature
-10°C
+35°C
Atm. humidity max. 85% (exposure to dew not permissible)
Encl. protection type/standards IEC60669, EN55022 / EN50081-1 and
EN55024 / EN50082-1
Order number, description 09 501 138, Shutter control unit DRO 1U
Min.
Typ.
Max.