background image

d3m

Page 7

User's Guide V1.2

  Two or more 

d3m

 are in use: In this case the Midi in/outputs of all 

d3m

 are daisy

chained. Midi out of the first d3m is connected to Midi in of the second, Midi out of the
second d3m is connected to Midi In of the third and so on. The Midi output of the last
d3m in the chain is connected to Midi In of the device to be controlled by the d3m (e.g. a
computer that runs Native Instruments' B4 or Emagic's evb3, or an organ sound
generator) via a suitable Midi cable. The Midi input of the first 

d3m

 remains unconnected

in this case. Each 

d3m

 requires a different Midi channel to be able to distinguish the

keyboards (see operation how to assign a Midi channel).

  Two or more 

d3m

 are in use in combination with a 

d3c 

controller: The 

d3m

 and 

d3c

 are

daisy chained as described above but the 

d3c

 has to be the last link in the chain. The

Midi output of the 

d3c

 is connected to Midi In of the device to be controlled by the d3m

(e.g. a computer that runs Native Instruments' B4 or Emagic's evb3, or an organ sound
generator) via a suitable Midi cable. The Midi input of the first 

d3m

 remains unconnected.

Even in this case each 

d3m

 requires a different Midi channel to be able to distinguish the

keyboards (see operation how to assign a Midi channel).

Remark: The Midi input of 

d3m

 should be used only for connection to another 

d3m

 module.

The Midi input is not suitable for large amounts of Midi data (e.g. SysEx strings or Midi
messages coming from a computer sequencer) but only for small data rates like the
messages of another 

d3

 module. In case of large amounts of incoming Midi messages data

loss or delay may occur.

FOOT CONTROL 

q

This stereo jack socket can be used to connect a foot controller. Do not connect the foot
controller unless the 

d3m

 is switched off. The foot controller function is programmable (e.g.

volume, expression). For details please refer to the operation chapter. We recommend the
usage of the foot controller FP5. The foot controller is not included with the d3m and has to
be ordered separately if required. You may use even another foot controller that is connected
in this way:

If you do not want to use a foot controller the socket remains unconnected.

FOOT SWITCH 

r

This monophonic jack socket can be used to connect a (single) foot switch. Do not connect
the foot switch unless the 

d3m

 is switched off. The foot switch function is programmable

(e.g. rotary speakers, sustain). For details please refer to the operation chapter. We
recommend the usage of the foot switch VFP1. The foot switch is not included with the d3m
and has to be ordered separately if required. You may use even another foot switch that
uses a contact that is closed at rest (and opens when operated).

If you do not want to use a foot switch the socket remains unconnected.

high

end

low

end

10-100k linear

Foot control connection

Summary of Contents for d3m

Page 1: ...DOEPFER Organ Keyboard d3m User s Guide...

Page 2: ...mid or wet environment nor near inflammables No liquids or conducting materials must get into the instrument If this should happen the instrument must be disconnected from power immediately and be exa...

Page 3: ...d companies Any firmware update is not free of charge The costs for material working time and shipment is charged to the customer You may even carry out firmware updates yourself at your own risk In t...

Page 4: ...ing and Safety Instructions 2 Servicing Updates 3 Introduction 5 Connections rear panel 6 Power Supply n 6 MIDI OUT o MIDI IN p 6 FOOT CONTROL q 7 FOOT SWITCH r 7 Operation 8 Play Mode 9 B4 Mode 9 EVB...

Page 5: ...the foot controller and sustain or rotary speaker on off for the foot switch The keyboard is equipped with Midi In and Midi Out Two or even more of these manuals can be daisy chained via midi out in...

Page 6: ...um current has to be a multiple of 100 mA e g 200 mA for two d3m 300 mA for three d3m Remark The value 250mA printed on the rear panel is no longer required For the new series of d3m a current of 100...

Page 7: ...connection to another d3m module The Midi input is not suitable for large amounts of Midi data e g SysEx strings or Midi messages coming from a computer sequencer but only for small data rates like t...

Page 8: ...play mode is the normal operation mode that is used to play on the keyboard send program change messages with the buttons and operate the foot controller and foot switch to transmit the corresponding...

Page 9: ...sage 0 is transmitted Pay attention that most manufacturers count the Midi program change numbers from 0 127 others from 1 128 In this manual we use the range 0 127 as this is more common If the devic...

Page 10: ...sed in the EVB3 mode for certain functions that cannot be stored in the EVB3 presets These functions are controlled live i e while playing on the keyboard The following table shows the function of the...

Page 11: ...Leslie On Off toggle Foot control operated Foot control released 3 Leslie Fast Slow 4 Leslie Slow Fast 5 Leslie On Off 6 Leslie Off On 7 Sustain On Off 8 Sustain Off On 9 Vibrato On Off toggle 10 Vib...

Page 12: ...006 by Doepfer Musikelektronik GmbH Geigerstr 13 82166 Graefelfing Germany Phone 49 89 89809510 Fax 49 89 89809511 email sales doepfer de Web Site www doepfer com Doepfer Musikelektronik www doepfer c...

Reviews: