background image

5

MN16022

LONG-TERM STORAGE

NOTE: Unless an extended warranty has been negotiated 

prior to sale, time in storage is considered time in service for 

warranty purposes.

If the drive is not installed immediately, it should be stored in a 

clean, dry, protected area. During periods of long term storage 

(six months or longer) special procedures must be followed. The 

unit should be filled to the highest oil level hole with an approved 

lubricant blended with 2%, by volume, of “Daubert Chemical Co. 

Nox-Rust VCI-105” oil. Apply a thick coating of rust preventative 

on all unpainted surfaces including threads, bores, keyways, 

and shafts. Apply a thick coating of chassis-type grease to all 

exposed shaft seals. If the unit is to be stored outdoors or in a 

damp, unheated area indoors, cover the entire exterior with a 

rust preventative. Seal the unit in a moisture proof container 

or wrapping with a desiccant inside. Shade the enclosure from 

direct sunlight. Rotate the input shaft at least 60 revolutions once 

a month to redistribute the lubricant and prevent brinnelling of 

bearings and drying of seals.
Upon removal from storage, remove all protective coatings 

applied for protection during storage. Check all hardware 

for proper tightness. Drain and refill the gear reducer with a 

recommended lubricant. If the gear reducer has been stored 

for more than three years or in an area with high ambient 

temperatures, replace the oil seals.

INSTALLATION AND OPERATION

Dodge Quantis UK RHB Reducers are shipped with filling, oil 

level and drain plugs in place. Add or drain oil to get to the correct 

oil level for the mounting position used.
Review the dataplates on the reducer and drive motor to verify 

that the drive is correct for the intended loads, speeds and power 

supply. The gear reducer should be installed in a location that 

meets the following requirements:

•  Ambient temperatures below 105°F (41°C).

• 

Free flow of air around the motor.

•  Good access to gear reducer and motor for maintenance.

• 

A flat, level, rigid steel mounting surface.

•  All four feet of the foot-mounted unit must be evenly 

supported.

• 

The flange mounted unit must have even support at the 

flange face.

• 

Units supported by both flange and feet must be shimmed to 

avoid housing stress.

•  Good alignment to both input and output devices.

INSTALLATION OF COMPONENTS ON GEAR 

REDUCER SHAFTS

Use care when installing couplings, sprockets and sheaves 

(pulleys) on the Dodge Quantis UK RHB input and output shafts. 

Such components should not be hammered into place. Damage 

to shafts and bearings may result. If parts do not slip into place 

easily, check for dirt or burrs that may be binding the assembly. 

Very tightly fitted parts may need to be heated to get them onto 

the shafts. Keys should be located for maximum engagement 

between the shaft and the associated part. Sprockets and 

sheaves should be mounted as close to the gearcase as possible 

to minimize overhung loads. Retaining hardware (setscrews, 

etc.) for couplings, sprockets and sheaves should be tightened 

as recommended by the component manufacturer. Chain and 

belt drives must be aligned to run true. Tighten chains and 

belts according to the chain or belt manufacturer’s instructions. 

Excessive tension results in rapid chain and belt wear and 

reduces the bearing life of the Dodge Quantis RHB unit.

Bottom of Key

Correct key fit in Motor Keyway 

Incorrect key fit in Motor Keyway 

2   Reducer Input Bore

1   Clamp Collar

Figure 1 - Clamp Collar Assembly

Figure 2 - Clamp Collar Motor Key Fit

Summary of Contents for Quantis Ultra Kleen

Page 1: ...n Company Inc invoice be withheld awaiting claims adjustment The carrier not Dodge guarantees safe delivery If considerable damage or shortage has occurred and the situation is urgent contact the near...

Page 2: ...omplex thickener and ISO 220 viscosity mineral oil base lubricant Use 15 pumps of grease for the first re greasing and 5 pumps of grease for subsequent re greasing Dodge Quantis Ultra Kleen RHB Reduce...

Page 3: ...bricant Selection Table Ambient Temperature OilType ISO ViscosityGrade AvailableOils AvailableFoodGradeOils NSF H1 45 Fto105 F 7 Cto41 C MineralOil 460 ChevronFM460 10 Fto105 F 12 Cto41 C MineralOil 2...

Page 4: ...Catalog and contact Application Engineering NOTE The oil volumes shown are approximate values and cannot be used to correctly set the reducer oil level ALWAYS fill the reducer to the correct oil level...

Page 5: ...s on the reducer and drive motor to verify that the drive is correct for the intended loads speeds and power supply The gear reducer should be installed in a location that meets the following requirem...

Page 6: ...he motor flange holes line up with the C Face adapter holes Check to be sure the motor conduit box grease fittings and condensate drains where fitted will be oriented as needed by the reducer mounting...

Page 7: ...6 After the gearbox has been pulled completely onto the machine shaft firmly against the machine shaft s backing shoulder it must be locked in place with the retaining bolt tightened to the tightenin...

Page 8: ...uld be 0 01 in for inch bore shafts Bold shaft diameters indicate standard shaft RS dimension is the minimum recommended shaft shoulder diameter Table6 MetricShaftsforStraightHollowBoreInstallation Di...