3
MN3082
RTL Series
A Circulating Oil Inlet Kit is required for each pillow block for the
Cool Lube 2 installation. Install the Circulating Oil Inlet Kit as
shown in the Sleevoil Instruction Manual (see Figure 5).
RTL Circulating Oil Inlet Kit
Part No.
RTL 2-15/16” thru 5-7/16” Circulating Oil Inlet Kit
132203
RTL 6” thru 12” Circulating Oil Inlet Kit
132205
The user shall provide connection adapters and tee fittings to
connect the supply lines to the circulating oil inlets. A tee fitting
is required at the inlet connection because these pillow blocks
have 2 circulating oil inlets. The tee fitting ensures both oil inlets
receive an equal amount of oil. Flexible connections from the
tee fitting to the oil inlets are recommended (see Table 4 for inlet
connection size).
Table 4–RTL Series
Bore Size
Number of
Circulating
Oil Inlets
and Outlets
Circulating
Oil Inlet
NPT Size
(Female)
Circulating
Oil Drain
Hole NPT
Size
Alternate Oil
Gauge Hole
NPT Size
2-15/16"
2
3/4 - 14
1 - 11-1/2
3/4 - 14
3-7/16"
2
3/4 - 14
1 - 11-1/2
3/4 - 14
3-15/16"
2
3/4 - 14
1 - 11-1/2
3/4 - 14
4-7/16"
2
3/4 - 14
2 - 11-1/2
3/4 - 14
4-15/16"
2
3/4 - 14
2 - 11-1/2
3/4 - 14
5-7/16"
2
3/4 - 14
2 - 11-1/2
3/4 - 14
6"
2
1 - 11-1/2
2 - 11-1/2
3/4 - 14
7"
2
1 - 11-1/2
2 - 11-1/2
3/4 - 14
8"
2
1 - 11-1/2
2 - 11-1/2
3/4 - 14
9"
2
1 - 11-1/2
2 - 11-1/2
3/4 - 14
10"
2
1 - 11-1/2
2-1/2 - 8
3/4 - 14
12"
2
1 - 11-1/2
2-1/2 - 8
3/4 - 14
RXT Series
A Circulating Oil Inlet Kit is NOT required for these pillow blocks.
The circulating oil inlets are machined into the housing and are
plugged with pipe plugs as shown in the Sleevoil Instruction
Manual (see Figure 6).
The supply line should be connected to the two inlets on the
downswing side of the pillow block for base loaded applications,
or to the two inlets on the upswing side for cap loaded
applications.
The user shall provide connection adapters and tee fittings to
connect the supply lines to the Sleevoil circulating oil inlets. A
tee fitting is required at the inlet connection because these pillow
blocks have 2 circulating oil inlets. The tee fitting ensures both
oil inlets receive an equal amount of oil (see Table 5 for inlet
connection size).
Table 5–RXT Series
Bore Size
Number of
Circulating
Oil Inlets
Circulating
Oil Inlet
NPT Size
(Female)
Circulating
Oil Drain
Hole NPT
Size
Alternate Oil
Gauge Hole
NPT Size
2-15/16"
2
1/2 - 14
1-1/4 - 11-1/2 1-1/4 - 11-1/2
3-7/16"
2
1/2 - 14
1-1/4 - 11-1/2 1-1/4 - 11-1/2
3-15/16"
2
1/2 - 14
2 - 11-1/2
2 - 11-1/2
4-7/16"
2
1/2 - 14
2 - 11-1/2
2 - 11-1/2
4-15/16"
2
1/2 - 14
2 - 11-1/2
2 - 11-1/2
5-7/16"
2
1/2 - 14
2 - 11-1/2
2 - 11-1/2
6"
2
3/4 - 14
2-1/2 - 8
2-1/2 - 8
7"
2
3/4 - 14
2-1/2 - 8
2-1/2 - 8
8"
2
3/4 - 14
2-1/2 - 8
2-1/2 - 8
9"
2
3/4 - 14
2-1/2 - 8
2-1/2 - 8
10"
2
1 - 11-1/2
2-1/2 - 8
2-1/2 - 8
12"
2
1 - 11-1/2
2-1/2 - 8
2-1/2 - 8
Figure 5 - RTL Circulating Oil Inlets
Figure 6 - RXT Circulating Oil Inlets
Summary of Contents for Cool Lube 2