These symbols are internationally accepted symbols that warn of potential
hazards with electrical products.The lightning flash means that there are
dangerous voltages present within the unit.The exclamation point indicates
that it is necessary for the user to refer to the owners manual.

These symbols warn that there are no user serviceable parts inside the unit.
Do not open the unit. Do not attempt to service the unit yourself. Refer all
servicing to qualified personnel. Opening the chassis for any reason will void
the manufacturer’s warranty. Do not get the unit wet. If liquid is spilled on
the unit, shut it off immediately and take it to a dealer for service.

Disconnect the unit during storms to prevent damage

.

U.K. Mains Plug Warning

A molded mains plug that has been cut off from the cord is unsafe.
Discard the mains plug at a suitable facility. Never under any circum-
stances should you insert a damaged or cut mains plug into a 13
amp power socket. 
Do not use the mains plug without the fuse cover
in place. Replacement fuse covers can be obtained from your local retail-
er. Replacement fuses are 13 amps and MUST be ASTA approved to
BS1362.

Safety Instructions

Notice for customers if your unit is equipped with a power cord.

Warning:This appliance must be earthed.

The cores in the mains lead are colored in accordance with the following
code:

Green and Yellow - Earth  Blue - Neutral

Brown - Live

As colors of the cores in the mains lead of this appliance may not corre-
spond with the colored markings identifying the terminals in your plug, pro-
ceed as follows:

•The core which is colored green and yellow must be connected to the

terminal in the plug marked with the letter E, or with the earth sym-
bol, or colored green, or green and yellow.

•The core which is colored blue must be connected to the terminal

marked N, or colored black.

•The core which is colored brown must be connected to the terminal

marked L, or colored red.

This equipment may require the use of a different line cord, attachment
plug, or both, depending on the available power source at installation. If the
attachment plug needs to be changed, refer servicing to qualified service
personnel who should refer to the table below.The green/yellow wire shall
be connected directly to the unit’s chassis.

Warning: If the ground plug is defeated, certain fault conditions in the unit
or in the system to which it is connected can result in full line voltage
between chassis and earth ground. Severe injury or death can then result if
the chassis and earth ground are touched simultaneously.

LIVE

E

NEUTRAL

EARTH GND

CONDUCTOR

L

N

BROWN

BLUE

GREEN/YEL

BLACK

Normal

Alt

WIRE COLOR

WHITE

GREEN

Warning

For your protection, please read the following:

Water and Moisture: Appliances should not be used near water
(e.g. near a bathtub, washbowl, kitchen sink, laundry tub, in a wet
basement, or near a swimming pool, etc.) Care should be taken so
that objects do not fall and liquids are not spilled into the enclosure
through openings.

Power Sources: The appliance should be connected to a power
supply only of the type described in the operating instructions or as
marked on the appliance.

Grounding or Polarization: Precautions should be taken so that
the grounding or polarization means of an appliance is not defeated.

Power Cord Protection: Power supply cords should be routed so
that they are not likely to be walked on or pinched by items placed
upon or against them, paying particular attention to cords at plugs,
convenience receptacles, and the point where they exit from the
appliance.

Servicing: To reduce the risk of fire or electrical shock, the user
should not attempt to service the appliance beyond that described in
the operating instructions. All other servicing should be referred to
qualified service personnel.

For units equipped with externally accessible fuse recepta-
cle: 
Replace fuse with same type and rating only.

Electromagnetic Compatibility

Operation is subject to the following conditions:

•This device may not cause harmful interference.
•This device must accept any interference received, including

interference that may cause undesired operation.

•Use only shielded interconnecting cables.
•Operation of this unit within significant electromagnetic fields

should be avoided.

Summary of Contents for SR 834

Page 1: ...SR Series Crossovers Owner s Manual SR 823 SR 834 A Harman International Company ...

Page 2: ...ing on the available power source at installation If the attachment plug needs to be changed refer servicing to qualified service personnel who should refer to the table below The green yellow wire shall be connected directly to the unit s chassis Warning If the ground plug is defeated certain fault conditions in the unit or in the system to which it is connected can result in full line voltage be...

Page 3: ...eaner overall sound and a significant decrease in the amount of power needed to drive the system to the same levels as a full range amplified system with more power The greatest power demands in a sound system are made by the low frequencies of the program material This is because music and voice signals contain mostly low frequency information and low frequency drivers are generally less efficien...

Page 4: ...connection All inputs and outputs are balanced Use XLR type male plugs for inputs and female plugs for outputs For balanced operation using 1 4 phone plug connectors use only tip ring sleeve stereo jacks For unbalanced operation using 1 4 phone plug connectors use only tip sleeve mono jacks FOR BALANCED CONNECTION Wire XLR connections as follows Pin 2 high Pin 3 low Pin 1 ground or common FOR UNBA...

Page 5: ...g to the front panel markings If below 180Hz is desired press the 10 switch on the rear panel SR834 Set the LOW MID crossover frequency for each channel according to the front panel markings If below 180Hz is desired press the 10 switch on the rear panel If the desired frequency is below 180 Hz the 10 switch must be engaged LED indicator lit If the desired frequency is above 180 Hz the Range switc...

Page 6: ...N THE POWER AMPLIFIER FOR THAT OUTPUT IS OFF Turning down the level controls will not prevent transients from appearing at the outputs when changing the phase switches while the crossover is on These transients can damage power amplifiers speakers and drivers STEREO OPERATION USING A MONO SUBWOOFER This mode of operation provides SR834 Channel 1 and Channel 2 high frequency outputs Channel 1 and C...

Page 7: ...n the front and rear panels will be followed instead of the top row Be sure that the amplifiers are off that the gain control is set to 0 dB and that the level control is set to 12 before proceeding to adjust the crossover frequencies and levels THE LOW FREQUENCY SUM OUTPUT IS NOT USABLE IN THE MONO MODE WARNING BEFORE PRESSING THE 10 LF SUM OR STEREO MONO SWITCHES LOWER THE OUTPUTS OF YOUR POWER ...

Page 8: ...d on each input Maximum Input Level Balanced 27dBu Unbalanced 27dBu Input Impedance Balanced 20kΩ Unbalanced 10kΩ OUTPUTS Type Electronically Balanced Connector XLR 3 M Polarity Pin 2 hot rear panel selectable Maximum Output Level 10kΩ Load 600 Ω Load Balanced 27dBu 27dBm Unbalanced 22dBu 20dBm Output Impedance Balanced 102Ω Unbalanced 51Ω PERFORMANCE THD Noise Less than 0 004 Crossover 1kHz 30kHz...

Page 9: ...065 1993 IEC63 1985 with Amendments 1 2 3 EMC EN 55013 1990 EN 55020 1991 Supplementary Information The products herewith comply with the requirements of the Low Voltage Directive 73 23 EEC and the EMC Directive 89 336 EEC as amended by directive 93 68 EEC DOD Electronics Corporation President of DOD 8760 South Sandy Parkway Sandy Utah 84070 European Contact Your local DOD Sales and Service Office...

Page 10: ... 8760 SOUTH SANDY PARKWAY SANDY UTAH 84070 TELEPHONE 801 566 8800 FAX 801 566 7005 INTERNATIONAL DISTRIBUTION 8760 SOUTH SANDY PARKWAY SANDY UTAH 84070 TELEPHONE 801 568 7638 FAX 801 568 7642 DOD IS A REGISTERED TRADEMARK OF HARMAN MUSIC GROUP INC 1999 DOD ELECTRONICS CORPORATION DOD 18 3700 ...