background image

Safety

The blue exclamation mark is an indication to the user about safety-relevant 
facts and facts relevant to service in this manual.

The listed safety regulations should be carefully observed. Please observe the following 
instructions and read this manual. For further questions please feel free to contact us.

We reserve the right to make changes to the design or specifications.

We reserve the right to make changes to the design or specifications.

We reserve the right to make changes to the design or specifications.

We reserve the right to make changes to the design or specifications. If you need help, if you have questions or if you have
a defect on the device, please contact us. We're here to help. 

IMC5

3

© DOCtron 2021

1. Always use a properly grounded power cord for this product.

Please never remove the ground of the power plug. This connection ensures safe and quiet operation and 
is absolutely necessary for operation. 

2. When installing into a rack, be sure to provide adequate ventilation. 

The top and bottom ventilation slots are not decoration and should never be covered during operation. The
main reason for technical defects are mostly heat problems. In non-ventilated cabinets, use ventilation 
panels (1H) between units (even if they don't look very beautiful) to prevent heat build-up. 

3. Avoid places with strong magnetic fields. 

 

The housings of the device are designed to protect the sensitive electronics from EMI and RFI. For rack 
mounting, be sure to place devices with large power supplies or power amplifiers as far away from the unit
as possible in the rack. A separate routing of signal and power lines can also help to suppress EMI and 
RFI as much as possible. 

4. Protect your device from moisture and water splashes. 

 

If water has entered the housing, disconnect it immediately from the mains and send it to us for inspection 
to prevent major damage. 

5. If you feel unsure about having to open the device

 

 to make settings, check fuses or set / 

remove jumpers, please contact our support team. We're here to help. 

6. Before you open the device 

to change jumpers or make adjustments, be sure to 

unplug 

the power adapter before opening the case.

 Disconnect the device from the mains! Make 

sure that no foreign parts remain in the device after completion of the work. 

Summary of Contents for IMC5

Page 1: ...Martin Stimming s Instant Mastering Chain v 5 1 7 Set up and operating instructions Introduction 2 Safety 3 Overview 4 Circuit Parts In Detail 5 Tech Specs 14 IMC5 1 DOCtron 2021...

Page 2: ...accessible to everyone The result is a device that represents a milestone in technical and practical terms IMC is elaborately crafted by hand The inner values are excellent and the case also manufact...

Page 3: ...s are not decoration and should never be covered during operation The main reason for technical defects are mostly heat problems In non ventilated cabinets use ventilation panels 1H between units even...

Page 4: ...Overview Here is the entire circuit as a block diagram IMC5 4 DOCtron 2021 Figure 1 block diagram...

Page 5: ...sitive and negative supply voltages is carried out in the device by its own sub switching power supplies Due to the conductivity of the carbon casing material sufficient protection against the outside...

Page 6: ...In this case the negative Signal RING will be grounded IMC5 works internally unbalanced The problem here is often ground and ground loops resulting from multiple shielding In a stereo connection thus...

Page 7: ...sidechain The feed forward FF is the signal before the compressor tapped with feed backward FB after the compressor Newer compressors work almost exclusively with Feed Forward FF Many classics such as...

Page 8: ...ches one can regulate the parameters of the integrated compressor RATIO RATIO RATIO RATIO Ratio determines the ratio of uncompressed to compressed signal 1 1 5 is therefore a slight compression while...

Page 9: ...s If you choose to put DRIVE to the nuts position you will get a horrible distorted signal DRIVE to the nuts position you will get a horrible distorted signal DRIVE to the nuts position you will get a...

Page 10: ...tch phantom power off switch phantom power off because the protection can degrade the audio signal SIDECHAIN SIDECHAIN SIDECHAIN SIDECHAIN With SIDECHAIN SEND and RETURN you can influence the control...

Page 11: ...0 0186 primary voltage 90 264 V el power 10 Watt max Input Voltage Range 27 5 dBu Input Impedance 47 k PSRR 90 dB Max Output Level 24 dBu 20Hz load 600 Gewicht IMC 1000g Contact details Contact detai...