background image

11 of 11 

 

TROUBLESHOOTING 

 

Problem:   

Condition:   

Solution suggested:   

Burner won’t 

light   

Control knob is not in Maximum position (big 

flame). 

Turn control knob in Maximum position (big flame). 

LPG cylinder valve is closed / Empty. 

Open the valve / Replace LPG cylinder with a new one. 

Blockage in the injector. 

Clean or replace injector. 

Air in the gas circuit. 

Open gas line and bleed it (pressing 

control knob in) for not over 1 minute or until you smell gas. 

Low gas pressure. 

Replace LPG cylinder with a new one.   

Igniter fails. 

Use match to light burner; change battery or obtain new 

igniter and replace it

.

   

Burner won’t stay 

lit   

Dirty build up around burner. 

Clean dirty around the burner. 

Low flames or not full running around the 

burner. 

Flame spreader holes partially closed; clean the burner. 

Thermocouple is not operating correctly. 

Replace thermocouple (FSD). 

Low Gas pressure. 

Replace LPG cylinder with a new one. 

Burner flame is 

low   

Note: Do not 

operate appliance 

below 5 ˚C

 

Outdoor temperature is greater than 5 ˚C 

and LPG cylinder is less than 25 % full. 

Replace LPG cylinder with a new one.   

Gas pipe is bent or kinked. 

Straighten hose and perform leakage test on gas pipe. 

Control knob is fully Maximum position (big 

flame). 

Turn control knob to”OFF" position (full disk), let cool to 

room temperature and check burner and 

orifices for blockage. 

Carbon build-up   

Dirty or film on burner. 

Clean burner.   

Flash back 

(flame 

inside burner)

 

Burner ports are blocked. 

Switch OFF the appliance. Close LPG cylinder valve. Wait 

2 minutes, following the ignition procedure. Ignite burner. If 

problem continuous, switch-off. Contact your dealer. 

Thick black 

smoke   

Blockage in the burner. 

Turn control knob to "OFF" position, let the appliance to 

cool at room temperature and remove 

blockage and clean burner inside and outside. 

 
                                                             

If you can not solve trouble according to one of the mentioned solution, please contact your dealer 
or distributor responsible. 

Summary of Contents for 35441E

Page 1: ...se Warning Accessible parts may be very hot keep young children away This appliance must be installed in accordance with the rules in force and used only in a sufficiently ventilated space Consult ins...

Page 2: ...3 mm x 1 pcs Destination countries AT DE SK CH LU Gas regulator Certified regulator according to EN 16129 flow rate max 1 5kg h Gas hose Certified gas hose according to applicable EN standard max1 5m...

Page 3: ...y your self Never use this appliance until all connections have been leakage tested Never put it into operation if any leakage is detected check leakage all the time by soapy foam never using a flame...

Page 4: ...ay away to avoid burns or clothing ignition If fire should go out turn gas supply in OFF position full disk and wait for 2 minutes before attempting to relight Children should be carefully supervised...

Page 5: ...5 of 11 EXPANDED VIEW...

Page 6: ...re supplied with this appliance and must be used according to National Rules in force You need to purchase one gas regulator and one gas cylinder The gas regulator has to be set according to specific...

Page 7: ...aximum position big flame stop pushing ignition button star and keep the control knob pressed but not over 20 seconds to heat the thermocouple FSD then release it first ignition take generally more ti...

Page 8: ...ing to EN 549 Class B2 or material used to guarantee tightness according to EN 751 1 Class I GAS REQUIREMENTS Use only the type of gas and the type of LPG cylinder specified by the manufacturer Applia...

Page 9: ...inimum clearance is 1 m from combustible materials and or any wall side left right or back any ceiling is forbidden Appliance is not fitted with any guard it is recommended to use one for the protecti...

Page 10: ...embling battery Please contact the Manufacturer or dealer for information regarding replacement hoses thermocouples igniters lava rocks etc Attention Never use unauthorized parts or component for this...

Page 11: ...ressure Replace LPG cylinder with a new one Burner flame is low Note Do not operate appliance below 5 C Outdoor temperature is greater than 5 C and LPG cylinder is less than 25 full Replace LPG cylind...