DNF Controls 4000CL-MAV-PBIO User Manual Download Page 5

5

 

 

 

 

4000CL-MAV, 250 Clip Fast Access System,  for Sony MAV-555, with PBIO option

Getting Started . . .

2

.

SYSTEM DESCRIPTION

‰

 

NOW, production switchers can load & play video clips on Sony MAV DDRs.

‰

 

Use the EMEM or SNAPSHOT Learn & Recall functions of the production switcher to load
and play a video clip from a Recall or timeline.

‰

 

Use the Run and Trigger functions of the production switcher to Play, Stop or Recue the video
clip.

‰

 

Instantly load a video clip at the press of a button.

‰

 

Instantly load a FILL clip & KEY clip at the press of ONE button, then play out both channels
in sync.  LOOP up to 4 channels.

‰

 

Control up to 4 video channels individually or ganged.

FEATURES

The 4000CL-MAV-PBIO, 400 Clip Instant Access System consists of the ST300-SSM with
Cliplist software.

With this Option, the ST300 has 4 Peripheral Device Addresses, one for each VTR that it controls.
This allows the production switcher to control any and all VTRs connected to the ST300.

Upon receipt of the Learn command from the production switcher, the ST300 saves the CLIP IDs
of the currently loaded clips, the current time of each clip, the VTRs they are loaded on, and the
current GANG mode, into the appropriate Cue Point.

When the Recall command is received, the ST300 loads the “Learned” Clips onto the “Learned”
VTRs, cues the Clip to the “Learned” time, then restores the “Learned” GANG mode.

The Trigger function on the production switcher puts the selected VTRs into Play, Stop, Recue or
other available modes.

DEFINITIONS

‰

 

Throughout this document, “Video Server” refers to the MAV-555.

‰

 

The ST300-S/SM as the ST300.

‰

 

Words surrounded by brackets, for example, [

ENTER

], are keys on the ST300.

      [

XXX

] + [

XXX

] means hold the two keys down simultaneously.

‰

 

“Softkeys” are the row of keys directly below the display that perform multiple functions in
MENU and other modes.

Summary of Contents for 4000CL-MAV-PBIO

Page 1: ...o 4000CL MAV PBIO 4000CL MAV T PBIO 250 CLIP FAST ACCESS SYSTEM with Peripheral Bus Interface Option Sony DP Protocol for SONY MAV 555 Video Servers USER MANUAL 12843 Foothill Blvd Suite D Sylmar CA 9...

Page 2: ...ETUP 8 5 LOAD A CLIP 6 LEARN ON THE ST300 8 7 LEARN ON THE PRODUCTION SWITCHER 9 8 RECALL ON THE ST300 9 9 RECALL ON THE PRODUCTION SWITCHER 9 10 TRIGGERS FROM THE PRODUCTION SWITCHER 10 ADVANCED FEAT...

Page 3: ...ENCE 15 15 SETUP MENU 15 16 FUNCTION TABLE 17 17 SPECIFICATIONS 18 ST300 18 RS422 SERIAL CONNECTOR 18 POWER CONNECTOR 18 AUX CONNECTOR PBUS IN RS422 SERIAL CONNECTOR 18 GPI IN OUT CONNECTOR 19 18 KEY...

Page 4: ...4 4000CL MAV 250 Clip Fast Access System for Sony MAV 555 with PBIO option 1 REVISION HISTORY 120602 Rev 3 0 Added GPI s 040303 Rev 3 1 Added Key Layout...

Page 5: ...l Device Addresses one for each VTR that it controls This allows the production switcher to control any and all VTRs connected to the ST300 Upon receipt of the Learn command from the production switch...

Page 6: ...s To set the Device Address for each VTR a Press MENU and turn the Wheel until Peripheral Address is displayed b Press VTR 1 VTR 2 VTR 3 or VTR 4 to select a VTR c Assign a Peripheral Device Address f...

Page 7: ...7 4000CL MAV 250 Clip Fast Access System for Sony MAV 555 with PBIO option CONNECTION DIAGRAM...

Page 8: ...ric keypad d Press LOAD to load the desired clip e Repeat steps a d until clips are loaded into the desired VTRs Set the GANG mode if required Refer to the Function Table for Details f Press ESC at an...

Page 9: ...Select the desired Cue Point by pressing NEXT CUE LAST CUE OR By manually entering the Cue Point using the numeric keypad The selected Cue Point number is shown on the bottom line of the display b Pr...

Page 10: ...reset Speed 3 Reverse Play 4 Still Frame 5 None 6 or greater Play SONY Trigger Value Mode 0 Recue to beginning of clip 1 Play 2 Slo mo using ST300 Preset Speed 3 Reverse Play 4 Still Frame 5 None 6 or...

Page 11: ...he entered time and exit OR Press ESC to exit without saving NOTE Default record duration is 30 minutes d Select VTR Connection must be to the Recorder port on MAV 555 to create a clip e Press CLIP LI...

Page 12: ...int Press MARK to overwrite the saved time with the current time Press RECUE to search to the IN OUT point c CLEARING AN IN OUT POINT Press and hold DEL then press and release IN OUT The IN OUT indica...

Page 13: ...00 to the VTR4 connector of the receiving ST300 using an RS422 9 pin cable with TX and RX lines crossed A turnaround cable b Press MENU and scroll the wheel to Transmit CUE List YES Enter Exit ESC c P...

Page 14: ...ss MENU and scroll the wheel to Receive CUE List YES Enter Exit ESC c Press ENTER to start receiving The Display shows Waiting to receive d When the Transmitter is ready transfer starts automatically...

Page 15: ...ast wind speed 3 9 to 23 7 by pressing Softkey below SPD SLOMO ST300 display shows Non T Bar version ST300 display shows T Bar version NOTE The T BAR has a fixed speed range of 0 200 with a detent at...

Page 16: ...installed software is displayed PARITY In hardware version 3 0 only set the parity to the same as the switcher For hardware versions 2 0 and 2 1 no adjustment is provided or required RECORD Press Sof...

Page 17: ...t WIND Speed in MENU SHUTTLE SHUTTLE Select SHUTTLE mode and enable Wheel SLOMO SLOMO Press SLOMO to slo mo the VTR Turn the Wheel or move the T Bar if available to change the play speed Press SLOMO t...

Page 18: ...contrast Jog Shuttle Wheel With mechanical detents Optional T bar Slo mo 0 200 of Play Speed RS422 SERIAL CONNECTOR 9 Pin D Type Female Pin 1 Frame Ground 6 Receive Common 2 Receive A 7 Receive B 3 Tr...

Page 19: ...n GPI IN OUT CONNECTOR 15 Pin D Type Female DB15F Pin 1 GPI 1 Out Pin 9 GPI 1 In Play 2 GPI 2 Out 10 GPI 2 In Stop 3 GPI 3 Out 11 GPI 3 In Recue 4 GPI 4 Out 12 GPI 4 In Next cue 5 GPI 5 Out 13 GPI 5 I...

Page 20: ...20 4000CL MAV 250 Clip Fast Access System for Sony MAV 555 with PBIO option 18 KEY LAYOUT...