DNF Controls 4000CL-L User Manual Download Page 11

11 

      

4000CL-L, Vs.2.1, 400 Clip Fast Access System, Louth Protocol 

 

 

11.

 

TRANSFER CUE LIST 

 

a.

 

TRANSMIT CUE LIST FUNCTION 

 

The TRANSMIT CUE LIST function allows you to transmit your list of Cue Points to a 
PC, using the provided utility software on the PC, or to another ST300.  Transfer to a PC 
requires OpSuite 3.0 software, which runs on a Windows-based computer.  Contact DNF 
Controls for more information. 

 

1)

 

TO TRANSMIT CUE POINTS TO THE ST300 

 
a) 

Connect the VTR4 connector on the rear of the ST300 to the VTR4 
connector of the receiving ST300 using an RS422 9-pin cable with TX 
and RX lines crossed. 

      

(A “turnaround” cable) 

 
b) Press 

[

MENU

]. 

 
c) 

Scroll the wheel until “Transmit CUE List? YES=Enter, Exit=ESC” is 
displayed. 

 
d) Press 

[

ENTER

] to start transmitting.  

The Display shows “Waiting to transmit” on the first line. 

 
e) 

When the Receiver is ready, transfer starts automatically.  
The Display now shows “Transmitting cuelist.”  
 

f) 

After the transfer is over, the display shows “Transfer is over” for one 
second and then shows “Waiting to transmit” again.  

 
g) 

Connect another ST300 to transmit the list again.  

OR  

 
 Press 

[

ESC

] twice to exit the MENU mode. 

 

2) 

TO TRANSMIT CUE POINTS TO THE PC  

 
a) 

Connect the VTR4 connector on the back of the ST300 to one of the 
COM ports on the PC using a RS422 to RS232 adapter. 

 
b) 

Repeat steps b – g of “

TO TRANSMIT CUE POINTS TO THE 

ST300

,” Section 11.a.1). 

Summary of Contents for 4000CL-L

Page 1: ...col 12843 Foothill Blvd Suite C Sylmar California 91342 V 818 898 3380 F 818 898 3360 sales dnfcontrols com Model 4000CL L and 4000CL L T 400 CLIP FAST ACCESS SYSTEM Louth Protocol VERSION 2 1 SOFTWAR...

Page 2: ...OR CLIP COMBINATION 8 8 RECALL A CLIP OR CLIP COMBINATION 8 9 RECUE THE CURRENTLY LOADED CLIP 8 ADVANCED FEATURES 9 10 CREATE A CLIP 9 a SET THE RECORD DURATION 9 b CREATE A NEW NAME 9 c RECORD A CLI...

Page 3: ...3 4000CL L Vs 2 1 400 Clip Fast Access System Louth Protocol 1 REVISION HISTORY 022404 1 0 Original Document 080604 Rev 1 1 Changed T bar dimension 012705 Rev 1 2 Revised Key Layout...

Page 4: ...sign video clips to 400 locations in the SHOTLIST Enter a 1 2 or 3 digit number to access any location in the SHOTLIST Then LOAD and PLAY It s that easy Ideal for 9 Backup in case of On Air Automation...

Page 5: ...s connectors 1 Press MENU 2 Turn the wheel until VTR Louth Address is displayed 3 Press VTR 1 VTR 2 VTR 3 or VTR 4 to select VTR 4 Assign a Louth Port address by entering a style number 0 9 using the...

Page 6: ...6 4000CL L Vs 2 1 400 Clip Fast Access System Louth Protocol SYSTEM CONNECTION DIAGRAM...

Page 7: ...e list of CLIP IDs that are resident on the Video Server The CLIP LIST indicator will turn on c Turn the Wheel to view the existing CLIP IDs on the video server Turn the Wheel clockwise to scroll forw...

Page 8: ...Gang The rest of the Gang will be learned automatically e Press MARK to complete the LEARN OR Press ESC to exit without LEARNING The ST300 will LEARN save the VTR Number 1 2 3 4 loaded CLIP ID and cu...

Page 9: ...MENU to set the record duration to 1 hour b CREATE A NEW NAME 1 Press CLIP LIST The CLIP LIST indicator turns on The display will show CREATE NEW CLIP 2 Press LOAD The display will show the default CL...

Page 10: ...re clip Video input must be connected to the Record Channel The ST300 Port selected for recording must be an Input Port a minus number 1 Set the desired record duration as described in Section 10 a SE...

Page 11: ...X and RX lines crossed A turnaround cable b Press MENU c Scroll the wheel until Transmit CUE List YES Enter Exit ESC is displayed d Press ENTER to start transmitting The Display shows Waiting to trans...

Page 12: ...RX lines crossed A Turnaround Cable b Press MENU c Scroll the wheel until Receive CUE List YES Enter Exit ESC is displayed d Press ENTER to start receiving The Display shows Waiting to receive on the...

Page 13: ...heel clockwise SET LOUTH PORT Allows user to select Louth Port for each VTR Using the numeric key pad enter the LOUTH Port number for the video server channel to be controlled Press ENTER to select an...

Page 14: ...exiting SLOMO mode It is only changed by SHIFT SLOMO PRESET SLOMO ST300 SETUP Press Softkey beneath ClearCues to clear all Cue Points to 00 00 00 00 Press Softkey YES when asked Are You Sure Press So...

Page 15: ...pad Press ENTER or RECUE to reload the currently loaded clip at the entered time JOG JOG Select JOG mode and enable Wheel LAST CUE LAST CUE Step to the previous Cue Point Location NEXT CUE NEXT CUE St...

Page 16: ...Power DB9M Aux DB9F Reference Video BNC Display Easy to read 2 line back lit LCD display User adjustable contrast Jog Shuttle Wheel With mechanical detents Optional T bar Slo mo 0 200 of Play Speed VT...

Page 17: ...ransmit B 8 Transmit A 4 Receive Common 9 Frame Ground 5 Spare GPI IN OUT CONNECTOR 15 Pin D Type Female DB15F Pin Description Function Pin Description Function 1 GPI 1 Out 9 GPI 1 In Play 2 GPI 2 Out...

Page 18: ...18 4000CL L Vs 2 1 400 Clip Fast Access System Louth Protocol 15 KEY LAYOUT...

Page 19: ...pair DNF Controls at its option will repair or replace the defective unit DNF Controls will return the unit prepaid to the customer The method of shipment is at the discretion of DNF Controls principa...

Reviews: