![DNF Controls 2044CL-EVS User Manual Download Page 15](http://html1.mh-extra.com/html/dnf-controls/2044cl-evs/2044cl-evs_user-manual_2514474015.webp)
2044CL-EVS, 300 Clip Instant Access System, EVS DDRs
15
PARAMETER DESCRIPTION
RECORD KEY
Select single button or 2-button record:
RECORD = [
REC
] Only
OR
RECORD= [
REC
] + [
PLAY
]
RECALL
MODE
Press [
NORMAL
] or [
REDIR
] (redirect).
REDIR-
When one and only one clip is learned into a Cue Point, the Clip will be REDIRECTED to load
on the currently selected VTR
NORMAL-
The cue point will load on the learned VTR.
PREROLL
Enter Preroll value.
RECORD
DELAY
Enter delay value. (Used by CAPTURE function.)
GANG
MODE
[
PERM
] Permanent Gang-
The GANG can be created and undone only with the [
GANG
] softkey.
[
TEMP
] Temporary Gang-
Quickly create a GANG by pressing and holding a VTR key, then pressing other VTR keys.
Quickly undo the GANG by pressing any VTR key.
Video Reference must be connected for frame accurate playout of ganged channels.
STANDARD
Press [
NTSC
] or [
PAL
] to select the video standard for time calculations.
LABEL
MODE
Press [
ON
] or [
OFF
] (See LABEL section for description.)
ON-
Display a user entered LABEL instead of the actual CLIP ID.
OFF-
Display actual CLIP ID.
CLEAR
MEM
[
DEFAULTS
] [
CLR – CUES
] [
CLR – BANK
] [
BACK
]
DEFAULTS
Set ST400 to factory defaults. Follow the prompts on the display.
Press [
YES
] to continue or press [
NO
] to exit without changing ST400.
CLR – BANK
Clears all cue points in the selected bank. Follow the prompts on the display.
CLR – CUES
Clears all cue points in all banks. Follow the prompts on the display.
BACK