Setting the output voltage 0-10V / 1-10V
The analog outputs output voltage is adjustable via the MODE-Jumper 3:
v
DMX-FAIL Function
The
DMX-Relais/Analog Interface 4
has a DMX-FAIL Function which stores the last
value in the case of a DMX-signal (HOLD) loss or uses a value set with RDM before.
The HOLD function can be activated via RDM or switch 10.
Switch 10 ON
DMX-HOLD active
Switch 10 OFF
DMX-HOLD not active
If HOLD is switched on (switch 10 = ON), the last received DMX values are kept in
case of a DMX signal failure.
If HOLD is switched off (switch 10 = OFF), the DMX values are replaced with a value
set by RDM in case of DMX signal failure. In delivery state this value is 0, so the
relays switch off.
In case of a power failure the held DMX values are rejected!
A value set by RDM is deleted when HOLD is selected.
After switching off the HOLD function the default value 0 is used!
0-10V
1-10V