background image

 

ArtNet DMX-UNIVERSE 4.1

 

17 

 

CE-Conformity 

 

This assembly is controlled by a microprocessor and uses high 
frequency. In order to maintain the properties of the module with 
regard to CE conformity, installation into a closed metal housing 
in accordance with the EMC directive 2014/30/EU is necessary. 
 

 

Risk-Notes 

 
You purchased a technical product. Conformable to the best available technology the 
following risks should not excluded: 

 

 

Failure risk:

 The device can drop out partially or completely at any time without 

warning. To reduce the probability of a failure a redundant system structure is 
necessary. 
 

Initiation risk:

  For the installation of the board, the board must be connected and 

adjusted to foreign components according to the device paperwork. This work can 
only be done by qualified personnel, which read the full device paperwork and 
understand it. 
 

Operating risk:

 The Change or the operation under special conditions of the 

installed systems/components could as well as hidden defects cause to breakdown 
within the running time. 
 

Misusage risk:

 Any nonstandard use could cause incalculable risks and is not 

allowed. 
 

Warning: 

It is not allowed to use the device in an operation, where the safety of 

persons depend on this device. 
 

Disposal 

 

Electronical and electronic products must not be disposed in 
domestic waste. Dispose the product at the end of its service life 
in accordance with applicable legal regulations. 
Information on this can be obtained from your local waste  
disposal company. 

 
 

 

 

 

Neutrik

®

 

is a registered trademark 

EtherCon

®

  

is a registered trademark 

Art-Net™  

Designed by and Copyright Artistic Licence Holdings Ltd. 

 

 

 

Summary of Contents for Art-Net DMX-UNIVERSE 4.1

Page 1: ...ArtNet DMX UNIVERSE 4 1 User manual Art Net Designed by and Copyright Artistic Licence Holdings Ltd...

Page 2: ...eters No special software is necessary a standard web browser is enough So the configuration is possible every time from PC Smartphone or tablet For an easy setting of the IP we provide the IP Configu...

Page 3: ...hannels Neutrik XLR3 DMX Output 4x 512 Channels or 4x 1024 Channels within Extension Mode Neutrik XLR3 All in and outputs are galvanically isolated Dimension 170 x 170 x 58mm Protocol ArtNet 3TM downw...

Page 4: ...ArtNet DMX UNIVERSE 4 1 4 Connection DMX OUT 1 DMX OUT 2 DMX OUT 3 DMX OUT 4 POWER 8 24V ETHERNET RESET LAN LED POWER LED DMX INPUT DMX INPUT LED...

Page 5: ...ia a web interface which can be called via any web browser Set the IP with IP Configurator The IP Configurator allows setting the IP Address and net mask setting also if the net work setting of the PC...

Page 6: ...will be used for the web interface Please set the net work card of your computer to this IP range to call the IP Address 2 0 0 10 via the web browser The network settings of the computer must be set...

Page 7: ...ssignment can occur clearly within the network Use in accordance to the ArtNet Specifications the IP Address 2 x x x or 10 x x x The Netmask is according to the ArtNet Specifications 255 0 0 0 TIP Any...

Page 8: ...eeds an own IP Address so the assignment can occur clearly within the network Use in accordance to the ArtNet Specifications the IP Address 2 x x x or 10 x x x TIP Any other IP Address can also be use...

Page 9: ...the DMX Data Via Sync the DMX Output of several Devices can be synchronized by usage the software Software MADRIX Framerate specifies the maximum DMX Frame rate MAX corresponds to the maximum frame r...

Page 10: ...ch 1 on ON Within the Extension Mode another ArtNet Node is activated which also has 4 Ports In the Web Configuration this is specified as Node 3 By activating the Extension Mode another Node is avail...

Page 11: ...Kan le Kanal 1 Kanal 512 Kanal 513 Kanal 1024 Example DMX Routing 450 Port 1 450 Kan le Port 2 512 Kan le Kanal 1 Kanal 450 Kanal 451 Kanal 1024 Kanal 962 If the value 0 is specified for the outputs 2...

Page 12: ...so the assignment within the network is clear Use in according to the ArtNet Specification the IP Address 2 x x x or 10 x x x TIP Any other IP Address can also be used e g 192 168 1 10 In this case t...

Page 13: ...own of the DMX Signal DMX FAIL NO DATA via ArtNet will be no DMX input received HOLD last DMX data the last data will be retained CLEAR all DMX channels to 0 all DMX channels will be set to 0 SET all...

Page 14: ...the device LAN LED flashes Release button Push button again and hold POWER LED flashes ca 10 seconds alternately Release the button during this time The Reset is executed and the POWER LED flashes 3x...

Page 15: ...VERSE 4 1 from list Click Firmware Update Select and confirm Firmware File bin Please wait until the update has finished If an error occurs you can begin from the start anytime Alternatively you can a...

Page 16: ...ArtNet DMX UNIVERSE 4 1 16 Accessory XLR Cable 3pin Several Lengths 1m 5m 10m 15m Network cable 5m...

Page 17: ...s according to the device paperwork This work can only be done by qualified personnel which read the full device paperwork and understand it Operating risk The Change or the operation under special co...

Page 18: ...d using electronic systems All information contained in this manual was arranged with largest care and after best knowledge Nevertheless errors are to be excluded not completely It is pointed out that...

Reviews: