Locally (Keypad)

To advance through the programming menu, press 

CMD

. To go back, press the Back Arrow key. To enter a 

menu, press any select key or area. To select an option, press the select key or area under that option.

Before programming, ensure the ECP panel’s IP address is set as default.

1.  Power up or reset the communicator.

2.  At the communicator keypad, enter 

6653

 (PROG) and press 

CMD

.

3.  Advance to 

SYSTEM OPTIONS

, then press any select key or area to enter the menu.

4.  Advance to 

KYPD INPUT

, then press any select key or area.

5.  Select 

ECP

 by pressing the third select key or area under that option.

6.  At 

ECP PARTN NBR

, enter the number of the partition where you want the communicator to operate. 

Range is 1 - 8. Default is 

1

.

7.  To save programming, advance to 

STOP

 and press any select key or area.

8.  At the communicator keypad, enter 

2313

 (DIAG) and press 

CMD

.

9.  Advance to 

ECP SETUP

 and press any select key or area.

10.  At 

ECP SETUP VISTA 128?

: If the panel is a VISTA 128, select 

YES

. Otherwise, select 

NO

.

11.  At 

INST CODE

, enter the ECP panel installer code and press 

CMD

.

12.  After configuration is finished, the keypad advances to 

GET ZONES

. Press any select key or area. 

As the communicator retrieves zones from the ECP panel, the number of zones is displayed and incremented 
as 

ZONE CT

 (zone count).

Troubleshooting

Message

Meaning

Next Steps

PROGRAMMING

The communicator is attempting to 
configure ECP panel programming 
settings for ECP Passthru.

Wait for the configuration attempt to complete. 
Afterward, a programming status message is 
displayed (success, fail, or busy).

PROGRAM SUCCESS

The ECP panel has been successfully 
configured.

Finish configuration at 

GET ZONES

.

PROGRAM FAIL

The ECP panel could not be 
programmed. 

Check wiring connections and communication 
settings, then retry programming. 

BUS IS BUSY

The ECP panel could not be 
programmed due to high ECP bus 
traffic.

Wait and retry programming or reduce traffic on the 
ECP bus, then retry programming.

Table 2: Programming Messages and Troubleshooting

Summary of Contents for Com Series

Page 1: ...HOW TO GUIDE ECP PASSTHRU...

Page 2: ...tep 3 Program the Vista Keypad 4 Step 4 Configure ECP Settings 4 Remotely Dealer Admin 4 Locally Keypad 5 Troubleshooting 5 Step 5 Remote Programming 6 Set up Remote Link 6 Add the VISTA Panel in Comp...

Page 3: ...ttings remotely or locally Required Materials The following software and hardware components are required to perform system takeovers Compatible Honeywell VISTA panel refer to VISTA Panel Compatibilit...

Page 4: ...to the ECP Bus of a VISTA panel See Table 1 and Figure 2 for the necessary wiring connections Caution Remove all AC and battery power from the panels before wiring 1 Attach the antenna to the SMA con...

Page 5: ...1 CABLE 1 2 3 4 5 6 7 8 OUT 17 12 AUX GND OUT 18 VISTA 20P ONLY VISTA 20P From DC From DC From Z4 From Z4 To Data In 6 To Data Out 7 To Negative 4 To Positive 5 DC Z1 Z2 Z3 G T R Z4 O1 O2 CellCom or D...

Page 6: ...emotely with Dealer Admin or locally with a programming keypad Remote programming requires communicators with firmware Version 212 or higher Local configuration requires communicators with firmware Ve...

Page 7: ...to ECP SETUP and press any select key or area 10 At ECP SETUP VISTA 128 If the panel is a VISTA 128 select YES Otherwise select NO 11 At INST CODE enter the ECP panel installer code and press CMD 12 A...

Page 8: ...you already have a basic communicator account added to your Remote Link accounts To enable ECP Passthru for that account complete the following steps 1 Right click Remote Link and select Run as admini...

Page 9: ...Compass 2 In the lower right corner of the Customers page select Add The Customer Detail window opens 3 In Subscriber Data enter a Receiver number and Account number 4 In the Panel Data section selec...

Page 10: ...the account that you created in the previous section 2 The Panel Editor opens Go to Tools Communications 3 Go to File Communication Settings 4 Select TCPIP Port Settings 5 To ensure that Compass uses...

Page 11: ...cation window press Connect 2 A dialog pops up to notify you that communication settings must be configured Press OK 3 Select Enable TCP IP 4 In the TCPIP Port dropdown select the appropriate TCP IP p...

Page 12: ...rs to manage their systems remotely including arming disarming viewing zone status bypassing zones view history manage users and more To use Virtual Keypad for remote management the configuration must...

Page 13: ...sarming Remote Zone Status Compatible with Compass VISTA 10SE Rev 15 or higher No No No No VISTA 10P Yes Yes Yes Yes Firmware version 2 0 or higher VISTA 15 Yes No No No No VISTA 15P Yes Yes Yes Yes F...

Reviews: