7000 Series Installation and Programming Guide | Digital Monitoring Products
11
If zone 2 does not restore (door closed) within the programmed time, the keypad
sounds every other second during the last ten seconds. If zone 2 restores prior to the
end of the programmed time, the keypad ends the bypass and indicates the open or
short zone condition to the panel.
Zone 2 Bypass Time (7073/A, 7173 only)
Enter the number of bypass seconds to elapse before the bypass timer expires. Range
is 20-250 seconds. Press any select key to enter the number of seconds. Default is
40
seconds.
Relock on Zone 2 (7073/A, 7173 only)
Select
NO
to leave the relay on when zone 2 faults to an open or short condition
during bypass. Select
YES
to turn the relay off when zone 2 faults open or short
during bypass. Default is
NO
.
Activate Zone 3 Exit (7073/A, 7173)
Select
YES
to enable the Request to Exit feature on zone 3. Select
NO
to allow
standard zone operation on zone 3. Default is
NO
.
When zone 3 shorts, the onboard Form C relay activates for the programmed
number of seconds. During this time, the user can open the protected door to start
the programmed bypass entry/exit timer. If the door is not opened within the time
programmed in the Zone 3 REX Strike Time, the relay restores the door to its locked
state.
Zone 3 REX Strike Time (7073/A, 7173)
Enter the number of REX seconds to elapse. Range is 5-250 seconds. Press any select
key to clear the keypad display and enter the number of seconds. The default is
5
.
Arming/Disarming Wait Time (7063/A, 7073/A, 7163, 7173)
Select the number of seconds (1-9) the keypad should wait when an area system
displays
ALL? NO YES
during arming/disarming or a HOME/SLEEP/AWAY system
waits during arming only. If a selection is not made before the delay expires, the
keypad automatically selects
YES
or
AWAY
. Select zero (
0
) to disable this feature.
The delay also occurs when any credential is presented for arming the Home/Sleep/
Away system. Default is
2
.
ZONE 2 BYPASS
TIME:
40
RELOCK ZONE 2
CHANGE:
NO
YES
ACTIVATE ZONE 3
EXIT:
NO
YES
ZONE 3 REX STRIKE
TIME:
5
ALL?: NO
YES
DELAY:
2