6
9800 Series Installation and Programming Guide | Digital Monitoring Products, Inc.
9800 Series Wireless Graphic Touchscreen Keypads provide a built–in survey capability
to allow one person to confirm keypad communication with the wireless receiver or panel.
This allows you to determine the best location for the keypad.
1.
Press
Options
in the carousel menu.
2. Press the installer options icon at the bottom-left corner of the screen.
3. Enter
3577
(INST) and press
CMD
.
4. Press the select key under
KPD RF
to start the survey communication. The keypad
displays its wireless serial number and
RF SURVEY
. Determine if communication is
confirmed or faulty.
Confirmed:
When successful communication has been established, the AC
Power/Armed LED turns blue.
Faulty:
If communication has not been established, the keypad AC Power/
Armed LED turns red. Relocate the device or wireless receiver until the survey
LED confirms clear communication.
SELECT A LOCATION