734 Installation and Programming Guide | Digital Monitoring Products
17
No Communication with Panel
Define the relay action when communication with the panel has not occurred for
5 seconds:
OFF
,
SITE
,
ANY
,
ON
, or
LAST
. Default is
OFF
. Press any select key or area
to change the default relay action:
Press the first select key or area to choose
OFF
(Relay Always Off). The relay does
not turn on when any Wiegand string is received.
OFF
does not affect any REX
operation. If communication is lost during a door strike, the relay remains on for the
door strike duration but turns off at the end of the door strike timer.
Press the second select key or area to choose
SITE
(Accept Site Code). Door access
is granted when the Wiegand site code string received matches any site code
programmed at Site Code. Refer to “Require Site Code” for more information.
Press the third select key or area to choose
ANY
(Any Wiegand Read). Access is
granted when any Wiegand string is received.
Press the fourth select key or area to choose
ON
(Relay Always On). The relay is
always on.
Press
CMD
to display additional actions. Press the first select key or area to choose
LAST
(Keep Last State). The relay remains in the same state and does not change
when communication is lost.
REMOVE KEYPAD
After programming is saved, the
REMOVE KEYPAD
option continually displays with
no timeout if the keypad remains connected to the module. After five seconds, the
piezo begins sounding continually. To disconnect the keypad and silence the piezo,
remove the keypad harness.
NO COMM WITH PNL
OFF
OFF
SITE ANY ON
OFF
SITE
ANY ON
OFF SITE
ANY
ON
OFF SITE ANY
ON
LAST
REMOVE KEYPAD