263LTE X1 SERIES INSTALLATION SHEET | DIGITAL MONITORING PRODUCTS
2
X1-8 Applications
Header
Cell Module
Standoff
2
3
Door Controller
Cell
Antenna
Cable
Cell
Module
Door
Controller
4
Standoff
Location
1
Tab
Door Controller
2
Cell
Antenna
Cable
Cell
Module
Door
Controller
1
Install the Cellular Communicator
1. Plug the included standoff into the door or elevator controller board.
2. Plug the cell module onto the standoff.
3. Plug the cell module into the cell header.
4. Screw on the cell module antenna cable to the antenna connector.
Remove the Cellular Communicator
1. Unscrew the antenna cable from the antenna connector.
2. Pinch the tab of the standoff to release the cell module from the door or elevator controller.
3. Unplug the cell module from the cell header.
4. If installing a new cellular communicator, go to step 2 of
Install the Cellular Communicator
above.
3
TEST THE CONTROLLER
Make sure that the reader LED(s) is on and the door or elevator controller’s power LED is on. Check that
the door or elevator controller is communicating with Dealer Admin and Virtual Keypad after Dealer Admin
programming is completed.
CONFIGURE CELL SETTINGS
Once connected to an X1, the communicator will automatically register with the cellular carrier upon power up.
Note:
The cellular communicator comes pre-activated, so it cannot be activated through Dealer Admin,
Remote Link, or by calling Customer Service.
2